Redring 570 installation instructions What to do if Things GO Wrong, Cleaning, Self Help

Page 4

temperature climbs above a set limit and the 'overheat' light will come on. This cut-out which gives an audible click, may also operate due to residual heat when the shower is switched off. It will reset itself if cold water is run through the shower for 10 to 20 seconds and the 'overheat' light will go out.

8.A pressure relief device is fitted to safeguard against extreme abuse conditions.

9.There are three defined plate spray settings adjustable by rotating the spray plate (see diagram 4). If desired many combinations between the 3 can be achieved.

Diagram 4

a)

'CASCADE'

 

(inner/outer)

b)

'SURF'

 

(outer spray

 

only)

HOW TO MAINTAIN YOUR 'REDRING' SHOWER

All water contains particles of lime which build up in the showerhead and unit reducing the performance. It is therefore important to clean the showerhead by regularly dipping it in a suitable de-scaling solution. The frequency of this will vary from weekly to quarterly.

Check the srayplate is then free to rotate to give the three setting. In some winter conditions, when incoming water from the cold water storage cistern is particularly cold it may be necessary to select the inner or outer spray pattern only. This will ensure correct operation of the shower with a slightly lower water flow rate.

NOTE:

After use it is normal for some water to drip from the shower head for a few moments.

Cleaning

It is recommended that the shower unit and accessories are cleaned using a soft cloth.

DO NOT use powerful abrasive or solvent cleaning fluids. It is advisable to switch off the shower at the isolating switch to avoid the shower accidently switching on.

WHAT TO DO IF THINGS GO WRONG

Self Help

If the performance of the shower does deteriorate in service make the following checks before calling out the contractor. Any one of these simple adjustments could restore the performance.

c)

'SPORT'

 

(inner spray

 

only)

Diagram 5

The spray head rotates through approximately 140o

IN ORDER TO MAINTAIN THE

PERFORMANCE OF YOUR

SHOWER YOU MUST CLEAN

THE SHOWERHEAD.

a)Water too

HOT

Increase water flow by adjusting the temperature control (knob B) anti-clockwise to a lower number on the temperature scale.

Clean the showerhead. Switch power to 'low power' setting .

Select outer or combination spray pattern.

Increase pressure of water supply e.g. fully open service valve.

Check hose is not kinked restricting the water flow.

4

Image 4
Contents Pumped Electric Shower Important Safety Instructions HOW to USE Your Redring ShowerHOW Your Redring Shower Works What to do if Things GO Wrong CleaningSelf Help Professional Service By power on lightHigh power setting Installation Instructions Redring After Sales ServicePressure Blockage on outlet i.e blocked Plumbing Fix the riser rail with screws providedDo not use solder fittings within 300mm of plastic fittings Electrical Model VariantModel Fuse TypeInstallation 33mm Earth Continuity 8mmAssembly of Riser RAIL, Handset and Soap Dish Page Guarantee