e)Water leaks Check for cause of high from burst pressure and remove it.

pressure Blockage on outlet i.e: blocked

relied valve

spray plate etc. Replace the

 

pressure relief disc.

 

 

REDRING AFTER SALES SERVICE

We offer a technical advisory service on the telephone to contractors and other customers with problems in the field.

Ring 0870 9000 430 (Normal Office Hours) Spare parts can be supplied against any VISA or Access cards.

Ring 0870 9000 420 (Normal Office Hours) Remember to quote the exact type of shower, as written on the front of the shower and on this leaflet. It may also be of use to have a note of the Catalogue Number as stated on the rating plate inside the shower.

A) Fixing the shower to the wall

The Redring Expressions 570 Pumped Electric Shower is fitted with a motor and some mechanical noise can be expected when in use. The type of wall structure will affect the noise levels. Solid walls will provide quieter operation than panel or stud partition walls.

Diagram 7a

Diagram 6

Diagram 7b

Service Valve

1ft (0.3 m) max,

6'6" (2 m) av. height from top of riser rail to base of bath or cubicle.

Cold Water

Cistern

Rising Main

3", 8cm min, 33ft (10 m) max, recommended heights between bottom of cold water cistern and top of shower unit.

INSTALLATION INSTRUCTIONS

The installation should be done by qualified personnel and checked by the Electricity Board.

WARNING: DO NOT INSTALL THE SHOWER IN A ROOM WHERE IT MAY BE SUBJECT TO FREEZING.

We recommend that the installation is done in the following sequence :-

A)Fixing the shower to the wall.

B)Plumbing.

C)Electrical connections.

1.Place the riser rail at the height recommended in diagram 7b and mark its position.

2.Position the heater so that the sides of the unit are vertical and the top is level with, or up to 0.3m (1ft) maximum below the top of the riser rail. Choose a flat piece of wall to avoid the possibility of distorting the backplate thus making the front cover a poor fit.

3.Adjust the positions to get the most convenient arrangement taking the following into account : -

a)The possible need to use the handset over the sink for hair washing etc.

6

Image 6
Contents Pumped Electric Shower Important Safety Instructions HOW to USE Your Redring ShowerHOW Your Redring Shower Works Cleaning What to do if Things GO WrongSelf Help By power on light Professional ServiceHigh power setting Redring After Sales Service Installation InstructionsPressure Blockage on outlet i.e blocked Fix the riser rail with screws provided PlumbingDo not use solder fittings within 300mm of plastic fittings Model ElectricalModel Variant Fuse TypeInstallation 33mm Earth Continuity 8mmAssembly of Riser RAIL, Handset and Soap Dish Page Guarantee