6. Technical Data

 

Working temperature Ta:

-20 ... +40°C

Storage temperature:

-20 ... +40°C

Operating time:

20 hours

Dimensions:

190 x 130 (L x diameter)

Weight:

approx. 1400 g

 

(with batteries)

IP-Rating:

IP 66

CE-marking:

0102

Power supply:

4 x LR20/R20

Bulb:

Halogen 4,8 Volt

 

and 0,5 Ampere,

 

Type H-141

7. Operating instructions

 

7.1. Handlamp

Please read through the following operating instructions in order to help enable the optimisation of all functions of the handlamp type H-4 DCA.

For your own information and safety please read the advice on the following pages.

7.2. Before use

Before use in the Ex-hazardous area, ensure that the handlamp head is screwed fully closed to the main casing. The handlamp can now be switched on and off with the sliding switch.

7.3. Opening

Warning: Do not open the handlamp within the Ex-hazardous area.

Before opening, switch to OFF. The handlamp head is removed by turning anticlockwise from the main casing – please note, that as the handlamp head is fitted with a high integrity seal, this action

14

Image 5
Contents DC a Contents Introduction Safety information Faults and damageEx-Data Safety regulationsOperating instructions Handlamp Technical DataBefore use OpeningBattery replacement Bulb replacementCleaning RepairsGuarantee and liability EC-Declaration of conformity EC-Certificate of conformity Page Ecom instruments GmbH