AIR AND LUBE REQUIREMENTS

WARNING HAZARDOUS PRESSURE. Do not exceed maxi9 mum inlet air pressure of 150 psi (10 bar). Operating pump at higher pressure may cause pump damage and/or personal inju9 ry and/or property damage.

Refer to general information sheet for additional safety precauD tions and important information.

Excessive air pressure will shorten the life of the pump.

For maximum operating efficiency, the following air supply specifiD cations should be maintained to this pump.

AIR PRESSURE - Up to 150 P.S.I. (10 Bar)

AIR FILTRATION - 50 micron

LUBRICATED AIR SUPPLY

AIR INLET SIZE - 1/4￿ NPTF

Filtered and oiled air will allow the pump to operate more efficiently and yield a longer life to operating parts and mechanisms.

Lack of or an excessive amount of lubrication will affect the perforD mance and life of this pump. Use the recommended lubricants.

DAILY: Fill air line lubricator with a good grade of S.A.E. NO. 90 W non-detergent gear oil, adjust to 1 to 2 drops per minute.

If pump is to be inoperative for more than a few hours at a time, disconnect air supply and relieve all pressure from the system.

It is recommended that an oiler be installed in the airline as close as possible to the pump. This increases the service life of the pump by reducing wear of the air motor's internal parts.

INSTALLATION

FLUSH PUMP

1.Connect fluid hose to pump outlet and be sure all fittings are tight.

2.Turn air regulator knob counter-clockwise until it turns freely.

3.Pump has been tested in oil and a small amount remains for protection against rusting. Immerse lower pump end in compatible solvent.

4.Connect air hose coupler to connector on FRL.

5.Turn air regulator knob clockwise until air motor starts operating.

6.Flush pump with oil.

7.Disconnect air supply from air motor.

CAUTION: Solvent used for flushing may not be compatible with material being pumped. If this is the case, flush again with a comD patible solvent.

If pump is to be inoperative for an unspecified period of time, disD connect air and relieve all pressure.

If pump does not function properly, disconnect air and relieve all pressure. Refer to Trouble Shooting.

OPERATING INSTRUCTIONS

1.Turn air regulator knob clockwise until air motor starts to cycle.

2.Allow pump to cycle slowly until it is primed and all air is purged from the fluid hose or dispensing valve.

3.Turn off dispensing valve and allow pump to stall-check all fittings for leakage.

4.Change air regulator setting until desired pressure and flow is obD tained.

5.Inspect airline filter, open petcock to flush moisture or residue from bowl.

6.Pump is recommended to operate between 30 PSI and 150 PSI (not to exceed 75 cycles per minute.)

MAINTENANCE

The basic pump consists of two major components: 1. Air Motor, 2. Lower Pump. The air motor is removable and is to be serviced sepaD rately. Refer to air motor manual for service and parts.

Periodically flush entire pump system with a solvent that is comD patible with the material being pumped.

Refer to disassembly procedures of air motor for correct breakD down.

Disassembly should be done on a clean work bench with clean cloths to keep parts clean.

If replacement parts are necessary, consult drawing containing parts for identification.

Before assembling, lubricate parts where required. When assemD bling ``O￿ rings or parts adjacent to ``O￿ rings, care must be exerD cised to prevent damage to ``O￿ rings and ``O￿ ring groove surfaces.

PUMP DISASSEMBLY

NOTE: All threads are right hand.

CAUTION: DO NOT mar finish on (10) or (22) tube.

1.Clamp pump assembly in a vise on the air motor base assembly.

2.Place a strap wrench around (4) tube and loosen by turning counD terclockwise. If the wrench slips on the (4) tube, wrap a piece of 400 sand paper around (4) tube and under strap wrench. (Note: Pipe wrench will damage the finish of the tube.

3.After the (4) tube has been pulled down to expose the (2) rod, hold air motor piston rod and unscrew the (2) rod from the air motor pisD ton rod.

4.Remove the air motor assembly from the vise.

5.Vise the lower pump and remove (22) primer tube from (10) tube.

6.Remove (21) cotter pin, (20) primer, (19) seat, (18) washer, (17) spacer, (16) body assembly (Disassemble body assembly if (14) ``u￿ cup or (15) spacer needs to be replaced.) and (12) washer from assembly.

7.Remove (10) tube from (4) tube. Remove (5) gasket.

8.Pull rod assembly from (10) tube and disassemble (9) adapter from

(7) plunger to remove (8) ball.

Page 2 of 4

72643-X-D

Image 2
Contents General Description Service KitsOperating and Safety Precautions Pump DataPump Disassembly InstallationMaintenance AIR and Lube RequirementsParts List Pump AssemblyTrouble Shooting No Material. Stalled Pump

72633-D specifications

The Ingersoll-Rand 72633-D is a high-performance rotary screw air compressor designed for various industrial applications. Renowned for its reliability and efficiency, this model is engineered to meet the rigorous demands of modern workplaces that require a consistent supply of compressed air.

One of the standout features of the Ingersoll-Rand 72633-D is its robust construction. This compressor boasts a durable design that can withstand tough operating conditions. It is built with high-quality materials that enhance its longevity, making it a worthwhile investment for businesses that rely on continuous air supply for their operations.

The Ingersoll-Rand 72633-D utilizes rotary screw technology, which allows for smooth operation and a high level of efficiency. This technology reduces the amount of energy consumed during operation, thus lowering operational costs significantly. In addition to energy efficiency, the rotary screw design minimizes noise levels, creating a more pleasant working environment.

Another key characteristic of the 72633-D is its advanced cooling system. The compressor features an innovative cooling design that maintains optimal operating temperatures even during prolonged use. This feature not only enhances performance but also extends the life of the unit by preventing overheating.

The compact design of the Ingersoll-Rand 72633-D makes it easy to install in various settings, from small workshops to large production facilities. Its space-saving footprint allows it to be positioned conveniently without compromising the overall layout of the workspace.

Furthermore, the 72633-D is equipped with user-friendly controls that provide operators with real-time data on performance metrics such as pressure and temperature. These controls enable users to monitor the compressor's operation easily and make necessary adjustments to optimize performance.

Additionally, the Ingersoll-Rand 72633-D includes advanced safety features that protect both the compressor and the surrounding environment. These features help prevent accidents and ensure that the compressor operates safely, adhering to industry standards.

In summary, the Ingersoll-Rand 72633-D is an exemplary rotary screw air compressor that combines durability, efficiency, and user-friendly technology. Its robust construction, advanced cooling system, and safety features make it an ideal choice for businesses seeking a reliable and powerful air compressor solution.