A) GENERAL MANUAL

A-1. INTRODUCTION

Thank you for choosing SHARP photovoltaic (PV) module. This Installation Manual contains essential information for electrical and mechanical installation that you must know before installing SHARP photovoltaic modules. These modules are listed to standard UL 1703. This Manual also contains safety information you need to be familiar with. All the information described in this Manual is the intellectual property of SHARP and is based on the technologies and experience that have been acquired and accumulated over the long history of SHARP. This Manual does not constitute a warranty, expressed or implied. SHARP does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in any way connected with installation, operation, use or maintenance of PV modules. No responsibility is assumed by SHARP for any infringement of patents or other rights of third parties that may result from use of PV modules. SHARP reserves the right to make changes to the product, specifications or Installation Manual without prior notice.

A-2. GENERAL INFORMATION (INCLUDING WARNING AND SAFETY)

The installation of PV modules requires a great degree of skill and should only be performed by qualified licensed professionals, including licensed contractors and licensed electricians. Please be aware that there is a serious risk of various types of injury occurring during the installation including the risk of electric shock. These SHARP PV modules are equipped with a permanently attached special cable assembly for ease of installation which does not require special assembly.

<GENERAL WARNING >

1.PV modules are heavy. Handle with care.

2.Before you attempt to install, wire, operate and maintain the PV module, please make sure that you completely understand the information described in this Installation Manual.

3.Contact with electrically active parts of a PV module such as terminals can result in burns, sparks and lethal shock whether the PV modules are connected or not.

4.PV modules produce electricity when sufficient sunlight or other light source illuminates the module. When modules are connected in series, voltage is cumulative. When modules are connected in parallel, current is cumulative. PV systems can produce high voltage and current which could present an increased hazard and may cause serious injury or death.

5.Do not connect PV modules directly to motor loads. Variation in PV module output power as a function of solar irradiance may damage directly-connected loads. For example,

1:In the case of a brushless motor, the lock function may become active and the motor may be damaged;

2:In the case of a brush type motor, the coil may be damaged.

6.Always use gloves when handling the module, never touch the glass surface with bare hands.

<GENERAL SAFETY >

1.Wiring and grounding method of the frame of arrays shall comply with national, regional and local codes, laws and standards.

2.PV modules should be installed and maintained by qualified personnel. Only installation/service personnel should have access to the PV module installation site.

3.Keep children away from PV modules.

4.Prior to installation, do not store modules outdoors or in a damp environment to prevent glass from damage due to white efflorescence.

5.When PV modules are installed on roofs or any other structures above ground, appropriate safety practices should be followed and appropriate safety equipment should be used in order to avoid possible safety hazards. Note that the installation of PV modules on some roof types may require the addition of fireproofing, as required by local building/fire codes.

6.Roof mounted PV modules are to be mounted over a fire resistant roof.

7.Only PV modules with the same cell size should be connected in series.

8.Follow all safety precautions of other components used in the system.

9.In order to avoid risk of injury or electrical shock, do not allow anyone to handle damaged PV modules if the person is unqualified or has limited knowledge of PV modules. Place defective PV modules in cartons so PV cells are completely shaded, because a defective PV module or module with broken glass may generate power even if it is removed from the system.

10.Avoid uneven shade on the PV module surface. Shaded cells may become hot (“hot spot” phenomenon) which may result in permanent damage to the module (e.g., solder joints may peel off).

11.Do not clean the glass surface with chemicals. Do not let water stay on the glass surfaces of PV modules for a long time. This creates a risk of permanent damage to the glass, such as white efflorescence, otherwise known as “glass disease,” which may cause reduced power output.

12.To avoid dirt accumulation or white efflorescence due to water accumulation, do not install PV modules horizontally (flat).

13.In case of snow build up, snow would be slide down easier on the module than other parts of the roof. When snow suddenly slide and fall off the module’s surface, it may fall to under the roof and reach nearby areas. Ensure that the installment of the modules would not cause any damage to objects (carport, bicycle, entrance) nearby. Apply appropriate safety measures and/or safety equipments (e.g. snow stopper) when necessary.

14.Do not expose PV modules to sunlight concentrated with mirrors, lenses or other means.

15.Turn off inverters and circuit breakers immediately, should a problem occur.

16.The maximum open circuit voltage must not be greater than the specified maximum system voltage. Voltage is proportional to the number of PV modules in series and is affected by weather conditions. For strings connected in parallel take proper measures to block reverse current flow.

- 1 -

Installation Manual for PV Modules

Image 1
Contents General Manual For Sharp Photovoltaic ModulesInstallation Safety Handling SafetyElectrical Installation Cable characteristicsGrounding Grounding Using Existing Ground Hole , GBL-4DBT MaintenanceGrounding Using Existing Ground Hole Mounting Using Frame Bolt Holes Figures Mechanical InstallationModule Specific Instructions Option a Table I. Minimum required dimensionsOption B Electrical Ratings Electrical InformationImportant Safety Instructions Where to Obtain Service Additional Items Excluded from Warranty CoveragePurchase will be required Damage incurred during transport