HUAWEI ME909 Series Mini PCIe Module |
|
Hardware Guide | Electrical and Reliability Features |
The above values are the average of some test samples.
LTE test condition: 10 MHz bandwidth, QPSK, 1RB when testing max Tx power and full RB when testing 1 dBm or 10 dBm.
5.7Reliability Features
Table
Table
Item |
| Test Condition |
| Standard |
|
|
|
|
|
| Temperature: |
| IEC60068 | |
storage |
| Test duration: 24 h |
|
|
|
|
|
| |
|
|
|
|
|
| Temperature: 85ºC±2ºC |
| IEC60068 | |
storage |
| Test duration: 24 h |
|
|
|
|
|
| |
|
|
|
|
|
| Temperature: |
| IEC60068 | |
working |
| Test duration: 24 h |
|
|
|
|
|
| |
|
|
|
|
|
| Temperature: 60ºC±2ºC |
| IEC60068 | |
working |
| Test duration: 24 h |
|
|
|
|
|
| |
|
|
|
|
|
Damp heat cycling |
| High temperature: 55ºC±2ºC |
| IEC60068 |
|
| Low temperature: 25ºC±2ºC |
|
|
|
| Humidity: 95% |
|
|
|
| Repetition times: 4 |
|
|
|
| Test duration: 12 h+12 h |
|
|
|
|
|
|
|
Temperature shock |
| Low temperature: |
| IEC60068 |
|
| High temperature: 85ºC±2ºC |
|
|
|
| Temperature change interval: < 30s |
|
|
|
| Test duration: 15 min |
|
|
|
| Repetition times: 100 |
|
|
|
|
|
|
|
Salty fog test |
| Temperature: 35°C |
| IEC60068 |
|
| Density of the NaCl solution: 5%±1% |
|
|
|
| Spraying interval: 8 h |
|
|
|
| Duration of exposing the module to |
|
|
|
| the temperature of 35°C: 16 h |
|
|
|
|
|
|
|
| Huawei Proprietary and Confidential | 42 | |