Description | Value |
|
| |
|
|
| ||
Number of Drives | Up To 3 SERCOS interface drives | |||
|
|
| ||
| Up to 8 SERCOS interface drives | |||
|
|
| ||
| Up to 16 SERCOS interface drives | |||
|
|
| ||
| Up to 8 SERCOS interface drives. You | |||
|
| must use drives that are Extended Pack | ||
|
| Profile compliant. |
| |
|
|
| ||
SERCOS interface | 4 Mbits or 8 Mbits per second | |||
Data Rate |
|
|
| |
4 Mbits or 8 Mbits per second | ||||
| ||||
|
|
| ||
| 4 Mbits or 8 Mbits per second | |||
|
|
|
| |
| 4 Mbits per second |
| ||
|
| |||
SERCOS interface | Important: Only Kinetix 6000 drives let you use a 0.5 ms cycle time. | |||
Cycle Time |
|
|
| |
Data rate | Number of drives | Cycle time | ||
| ||||
|
|
|
| |
| 4 Mb | up to 2 | 0.5 ms | |
|
|
|
| |
|
| up to 4 | 1 ms | |
|
|
|
| |
|
| up to 8 | 2 ms | |
|
|
| ||
|
| You can’t use more than 8 drives at a 4 Mb | ||
|
| data rate. |
| |
|
|
|
| |
| 8 Mb | up to 4 | 0.5 ms | |
|
|
|
| |
|
| up to 8 | 1 ms | |
|
|
|
| |
|
| up to 16 | 2 ms | |
|
|
|
| |
Plastic Fiber Optic | Transmission Range |
| ||
Cable |
|
|
| |
Core Diameter | 980μm ± 60μm |
| ||
|
| |||
|
|
|
| |
| Cladding Diameter | 1000μm ± 60μm |
| |
|
|
|
| |
| Cable Attenuation | 140 dB/km @ 650nm |
| |
|
|
|
| |
| Operating Temperature |
| ||
|
|
| ||
| Connector | |||
|
|
|
| |
| Bend Radius | 2.5 cm |
| |
|
|
|
|