TOA Electronics VF4000-CMP-2 dimensions Table of Contents

Page 2

TABLE OF CONTENTS

 

 

General Information

page

2

Inventory

page

2

Tools and Building Supplies

page

2

Installation Applications

page

2

Important Safety Information

page

2

Codes

page

3

Combustion and Ventilation Air

page

3

Location of Fireplace

page

4

Clearances

page

5

Preinstallation

page

5

Installation – Built-In

page

5

Connecting Gas Line

page

6

Gas Pressure Check

page

6

Electrical Wiring – Optional Blower . page

7

Finished Wall Details

page

8

Installation – Surround

page

8

Log Assembly

page

8

Flame Appearance

page

9

Optional Equipment

page 10

Forced Air Kit

page 10

Operation and Care

page

11

Cleaning and Servicing

page 11

Replacement Parts

page 11

Accessories/Components

page 12

Appliance Specifications

page 13

CH Operating Instructions

page 14

CM Operating Instructions

page 16

Troubleshooting Guide

page 17

Replacement Parts List

page 18

Replacement Parts

page 19

GENERAL INFORMATION

The VF4000 Series Unvented Room Heaters covered in this manual feature ceramic fiber split logs which glow realistically when the heater is operating.

These heaters are manually controlled. Models VF4000-CMN-2 and VF4000-CMP-2 feature a gas valve incorporating a millivolt operating system.

A spark ignition system (piezo) allows the heater pilot gas to be lit without the use of matches or batteries and permits operation of the heater during a power outage.

These heaters are fitted with a specially de- signed pilot (ODS) which responds to the amount of oxygen available in the room and shuts the heater off before the oxygen level drops below 18%. The pilot can be relit only when fresh air is available. Refer to the Com- bustion and Ventilation Air section.

The VF4000 Series Unvented Room Heaters may be built into a framed wall, or installed in an optional oak surround.

This heater has been tested to the standards of ANSI Z21.11.2 unvented heaters.

Do not install these unvented room heaters in a bedroom or bathroom as all units exceed maximum allowable BTU/Hr input of 10,000.

Inventory

Unvented Gas Fireplace Gas connection fittings

Installation and Operating Instructions

Tools and Building Supplies

Normally Required

Tools Should Include:

Phillips screwdriver

Hammer

Saw and/or Sabersaw

Measuring tape

Electric drill and bits

Pliers

Square

Piping complying with local codes

Pipe wrench

Tee joint

Pipe compound

Building Supplies Should Include:

Framing materials Wall finishing materials

Caulking materials (noncombustible) Fireplace surround materials

Installation Applications

1.Fireplace built into a framed wall.

2.Fireplace installed with oak surround and/ or platform (Refer to the SUR-5/6 unfin- ished oak veneer surround installation in- structions, P/N 903593).

Check the inventory list to be sure that you have all the necessary parts in usable condition. Also check for concealed damage.

IMPORTANT SAFETY INFORMATION

INSTALLER: PLEASE LEAVE THESE INSTRUC- TIONS WITH THE OWNER.

OWNER: PLEASE RETAIN THESE INSTRUC- TION FOR FUTURE REFERENCE.

IMPORTANT: BEFORE STARTING YOUR HEATER INSTALLATION, READ THESE INSTAL- LATION INSTRUCTIONS CAREFULLY TO BE SURE YOU UNDERSTAND THEM COMPLETELY AND IN ENTIRETY. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE A HEATER MALFUNCTION RESULTING IN SERI- OUS INJURY AND/OR PROPERTY DAMAGE.

WARNING: THESE APPLIANCES ARE DESIGNED TO OPERATE ON NATURAL OR PROPANE GAS ONLY. THE USE OF OTHER FUELS OR COMBINATION OF FUELS WILL DEGRADE THE PERFOR- MANCE OF THIS SYSTEM AND MAY BE DANGEROUS.

2

UNVENTED GAS ROOM HEATER SPECIFICATIONS AND TECHNICAL DETAILS

 

 

 

 

Valve

 

Regulator Pressure

Gas Inlet

Model No.

Gas Type

Maximum BTU/HR

Operation

Ignition

Setting

Pressure

 

 

 

 

 

 

 

VF4000-CHN-2

Natural

25,000

Manual

Piezo

5" w.c.

Max 10 ¹⁄₂" w.c.

VF4000-CMN-2

 

 

 

 

 

 

Min. 6" w.c.

 

 

 

 

 

 

 

VF4000-CHP-2

Propane/

25,000

Manual

Piezo

10" w.c.

Max 13" w.c.

VF4000-CMP-2

LPG

 

 

 

 

 

Min. 11" w.c.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 2
Contents Consumer Retain this manual for future reference Unvented Decorative Gas Fireplaces 903590 REV. N 12/2007Table of Contents Combustion and Ventilation AIR CodesMassachusetts And New York Require- ments MassachusettsLocation of Fireplace ExampleClearances PreinstallationInstallation Steps Built-In SystemsWith all Units VF4000-CMN/P Series Optional Wiring Diagram Assembling the Logs Surround InstallationsFinished Wall Details Appliance Operation Installing the Hood AssemblyFlame Appearance Optional Equipment Operation and Care of Your Appliance Cleaning and ServicingReplacement Parts Accessories and Components BSK-5Box VF4000 SpecificationsGas Line OpeningVF4000-CHM/P Operating Instructions Standard Valves What to do if YOU Smell GASPilot Pilot Location Lighting Instructions For Your Safety Read Before LightingVF4000-CMN/P Operating Instructions Millivolt Valves To Turn OFF GAS to ApplianceProducts Possible Cause RemedyVF4000-CHP Manual Replacement Parts ListVF4000-CHN Manual DescriptionReplacement Parts CM Models SIT Valve Shown CH Models903590 REV. N 12/2007