TOA Electronics VF4000-CMP-2 dimensions VF4000-CMN/P Series Optional Wiring Diagram

Page 7

A. Light the appliance (refer to safety and lighting instructions on pages 14 and 16).

B. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the gas control knob to the “OFF” posi- tion. Either tighten or refasten the leaking connection and retest as described above.

C. When the gas lines are tested and leak free, be sure to rinse off the leak testing solution.

D. When the gas lines are tested and leak free, observe the individual tongues of flame on the burner. Make sure all ports are open and producing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports.

VF4000-CMN/P Series

Optional Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.

From Thermocouple

 

Optional ON/OFF

 

Wall Switch/Rocker Switch

 

*

*

TH

Thermopile

 

 

 

TP

 

 

TPTH

 

 

Factory Wired

Field Wired

* For Rocker Switch Attachment Only.

Figure 11

Step 6. Installing the Optional Forced Air Blower Kit Wiring – A receptacle plate is provided for the installation of the FAB-1100 forced air blower kit (optional). Electrical power must be provided to this plate to oper- ate the blower.

Route a 3-wire, 120Vac power line with con- trol switch to the lower left front corner of the appliance. Supply wires are to be connected to the outlet as shown in Figure 12, ensuring that the polarity (as determined by the colors of the wires) is exactly as shown. The black and red wire loop must be left intact, with the mating connectors connected.

An external regulator must be used on all pro- pane (L.P.G.) heaters, in addition to the regula- tor fitted to the heater, to reduce the supply tank pressure to 13" w.c. (maximum).

WARNING: CONNECTING DIRECTLY TO AN UNREGULATED PROPANE TANK CAN CAUSE AN EXPLOSION.

Step 5. Installing the Optional Remote Wall Switch (VF4000-CMN/P models only) – The

millivolt system comes from the factory wired as shown in Figure 10. Select a convenient location for the remote wall switch and connect the wiring to the appliance (Figure 11 ).

CAUTION: DO NOT CONNECT THE OPTIONAL REMOTE SWITCH TO A 120V POWER SUPPLY.

Note: The optional rocker switch is mounted to the appliance and wired in the same way as the remote wall switch.

VF4000-CMN/P Series

Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.

From Thermocouple

* *

TH

Thermopile

TP

 

TPTH

 

* For Rocker or ON/OFF Wall Switch Attachment Only.

Figure 10

OFF/ON Blower

Wall Switch

 

To Fuse or

Black

Circuit Breaker

 

Receptacle

120V

White

}60HzAC

Fireplace

 

Junction Box

 

Blower Wiring Diagram

Ground Wire

Connection

White

 

 

(Supply)

 

Blower

 

 

 

 

(Lower)

 

 

Outlet

120 Vac

 

 

60 Hz

Bipolar

 

 

 

 

Terminal

 

Black

Screw

Black

(Supply)

 

Wire

Mating

Connectors

Red Wire

Figure 12

Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet.

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

7

Image 7
Contents Unvented Decorative Gas Fireplaces 903590 REV. N 12/2007 Consumer Retain this manual for future referenceTable of Contents Massachusetts CodesMassachusetts And New York Require- ments Combustion and Ventilation AIRExample Location of FireplaceBuilt-In Systems PreinstallationInstallation Steps ClearancesWith all Units VF4000-CMN/P Series Optional Wiring Diagram Finished Wall Details Surround InstallationsAssembling the Logs Flame Appearance Installing the Hood AssemblyAppliance Operation Optional Equipment Replacement Parts Cleaning and ServicingOperation and Care of Your Appliance BSK-5 Accessories and ComponentsOpening VF4000 SpecificationsGas Line BoxWhat to do if YOU Smell GAS VF4000-CHM/P Operating Instructions Standard ValvesPilot Pilot Location To Turn OFF GAS to Appliance For Your Safety Read Before LightingVF4000-CMN/P Operating Instructions Millivolt Valves Lighting InstructionsPossible Cause Remedy ProductsDescription Replacement Parts ListVF4000-CHN Manual VF4000-CHP ManualCM Models SIT Valve Shown CH Models Replacement Parts903590 REV. N 12/2007