A. Light the appliance (refer to safety and lighting instructions on pages 14 and 16).
B. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the gas control knob to the “OFF” posi- tion. Either tighten or refasten the leaking connection and retest as described above.
C. When the gas lines are tested and leak free, be sure to rinse off the leak testing solution.
D. When the gas lines are tested and leak free, observe the individual tongues of flame on the burner. Make sure all ports are open and producing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports.
VF4000-CMN/P Series
Optional Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.
From Thermocouple
| Optional ON/OFF | |
| Wall Switch/Rocker Switch | |
| * | * |
TH | Thermopile |
|
|
| |
TP |
|
|
TPTH |
|
|
Factory Wired | Field Wired |
* For Rocker Switch Attachment Only.
Figure 11
Step 6. Installing the Optional Forced Air Blower Kit Wiring – A receptacle plate is provided for the installation of the
Route a
An external regulator must be used on all pro- pane (L.P.G.) heaters, in addition to the regula- tor fitted to the heater, to reduce the supply tank pressure to 13" w.c. (maximum).
WARNING: CONNECTING DIRECTLY TO AN UNREGULATED PROPANE TANK CAN CAUSE AN EXPLOSION.
Step 5. Installing the Optional Remote Wall Switch
millivolt system comes from the factory wired as shown in Figure 10. Select a convenient location for the remote wall switch and connect the wiring to the appliance (Figure 11 ).
CAUTION: DO NOT CONNECT THE OPTIONAL REMOTE SWITCH TO A 120V POWER SUPPLY.
Note: The optional rocker switch is mounted to the appliance and wired in the same way as the remote wall switch.
VF4000-CMN/P Series
Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.
From Thermocouple
* *
TH | Thermopile |
TP |
|
TPTH |
|
* For Rocker or ON/OFF Wall Switch Attachment Only.
Figure 10
OFF/ON Blower
Wall Switch
| To Fuse or |
Black | Circuit Breaker |
| |
Receptacle | 120V |
White | }60HzAC |
Fireplace |
|
Junction Box |
|
Blower Wiring Diagram
Ground Wire
Connection
White |
|
|
(Supply) |
| Blower |
|
| |
|
| (Lower) |
|
| Outlet |
120 Vac |
|
|
60 Hz | Bipolar |
|
|
| |
| Terminal |
|
Black | Screw | Black |
(Supply) |
| Wire |
Mating
Connectors
Red Wire
Figure 12
Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. | 7 |