Note: If there is a room above ceiling level, firestop spacer must be installed on the bottom side of the ceiling. If an attic is above ceiling level, firestop spacer must be installed on top side of ceiling joist (Figures 21 and 22 ).

Room Above

Firestop Spacer

Figure 21

Attic Above

Firestop Spacer

Figure 22

CHIMNEY 30° OFFSET THROUGH FLOOR

OR CEILING

It may be necessary to assemble the chimney at 30° when passing through the floor or ceiling area. Use the F8FS30-2 firestop spacer as shown in Figures 23 and 24. Support the chimney at floor or ceiling penetration with a FTF8 stabi- lizer if distance of chimney below ceiling is 10' or more. Maintain 2" minimum air space to combustibles from chimney sections.

Attic Space

 

F8FS30-2

2" Min.

Firestop Spacer

 

Air Space

2" Min.

FTF8-S4 Stabilizer

Air Space

 

10'

 

Max.

30° Firestop

 

And Attic Above

Figure 23

Room Above

 

F8FS30-2

2" Min.

Firestop Spacer

 

Air Space

2" Min.

FTF8-S4 Stabilizer

Air Space

 

10'

30° Firestop

Max.

And Room Above

Figure 24

For Canada Only

When installing the chimney system through an open attic space, the attic shield assembly- firestop spacer must be used (Figure 25 ). This installation is required only for use in Canada.

Open Attic Space

Figure 25

Note: For Canadian installations, all chimney installedoutsidethebuildingmustbeconstructed with galvalume (outer sections only) effective January 1, 1992. The appropriate model desig- nations are located in the back of this manual.

Step 4. Note: Chimney sections are con- structed with a unique locking tab design, which ensures an immediate, tight assembly between sections. Plan your chimney require- ments carefully before assembly as chimney is difficult to disassemble after installation. If disassembled, the tabs might become dam- aged. Be certain tabs are properly formed to ensure locking tabs engage properly.

The Security FTF8 chimney system is a two piece chimney, which snap together from the fireplace up. Start with the inner flue section with the lanced end up, snap lock it in to the matching collar on top of the fire- place. At all subsequent joints, the upper flue section fits into the preceding flue sec- tion. Each piece snaps together by means of locking tabs (9 locking tabs per joint). Check each piece by pulling up slightly from the top to ensure proper engagement before installing the next section.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

If the flue has been installed correctly, it will not separate when you test it. Also, the inner flue joint where each section is joined should be tight and flat without gaps (Figure 26 ).

Figure 26

Outer pipe section installs in just the opposite way; the lanced end goes down and each new section goes OVER the outside of the previous section installed (Figure 27 ).

Locking Tabs (Lances)

Figure 27

Note: Assemble one component of chimney at a time (inner section first, then outer section last) before proceeding with the next complete section.

Continue to assemble the chimney up through framed opening. Assemble just enough to pen- etrate the roof flashing openings (Figure 28 ). Always maintain 2" minimum air space to com- bustible materials and always check each chim- ney joint (inner and outer) to ensure proper engagement. Check vertical alignment of chim- ney so that it projects from the roof in true vertical position.

1"* Min. Air Space To Combustibles

Figure 28

9

Image 9
Contents WH Report No. J9902-5865C-231 Wood Burning Fireplaces P/N 850,046M REV. a 12/2008Table of Contents Precautions Typical InstallationIntroduction Clearances and Height RequirementsChimney Height Assembly OutlineChase Enclosure Before You StartPRE-INSTALLATION Notes Assembly StepsInstalling the Fireplace ClearancesFront Fireplace SpecificationsLeft Side Right SideFraming Specifications Installing the Chimney System For Canadian Installations8d nails when completely installed Proceed with Steps 5 throughFor Canada Only Or CeilingUsing a FTF8-CTD Round Termination Roof Pitch Model Flat to 6/1212 to 12/12 TEN Foot Rule Summary Multiple TerminationsFTF8 Chimney Component Calculations FTF8 Vertical Elevation Chart Special Offset InstructionsOffset Calculations Stabilizer Offset Elevation ChartOffset Elbow Assembly Installing OffsetsReturn Elbow Assembly Optional Equipment ConsiderationsCombustion Air Kits Gas Line ConnectionVent Free Appliances Cold Climate Insulation Glass DoorsFireplace Finishes Mantels and TrimUsing the k formula Hearth Extension DimensionsWall Shield For the alternateSum of all R values is .70 + .10 + + .10 = Finish to Your TasteValue = 1/k = r x thickness of material used RM = rM x TS = 0.05 x 3/4 =Shipping Weight Installation ComponentsOrange, CA 850,046M REV. a 12/2008

RDI-36-H, HCI-36-H specifications

The Lennox Hearth HCI-36-H and RDI-36-H represent a pinnacle of innovation and efficiency in the world of gas fireplaces. These models are highly regarded for their combination of aesthetic appeal, advanced technology, and exceptional performance, making them an excellent choice for both new constructions and retrofitting existing spaces.

Starting with the HCI-36-H, this direct vent gas fireplace is designed for optimal heating while providing a stunning visual centerpiece. It features a sleek glass front that enhances the flame experience, showcasing the lifelike faux logs and glowing embers. The HCI-36-H is equipped with a powerful heat exchanger that maximizes heat output, ensuring your space remains warm and comfortable.

On the other hand, the RDI-36-H offers a more customizable experience. This model features a variety of decorative options, allowing homeowners to personalize their fireplace to fit their home’s aesthetic. From customizable front panels to decorative trim kits, the RDI-36-H is designed to cater to individual tastes while ensuring robust functionality.

Both models incorporate advanced technologies that improve energy efficiency and user experience. They utilize Lennox's patented flame technology, which creates a realistic fire while maintaining high efficiency. This technology also helps reduce emissions, making it an environmentally friendly choice. With an impressive efficiency rating, both units provide substantial warmth without excessive energy consumption.

User convenience is another significant aspect of these fireplaces. They come with an easy-to-use remote control, allowing you to adjust the flame height and heat output from the comfort of your couch. Additionally, the units offer a variety of safety features, including an automatic shut-off system that ensures peace of mind.

The HCI-36-H and RDI-36-H also boast a quick and straightforward installation process thanks to their direct vent capabilities, which minimize the need for extensive ductwork. This makes them ideal for existing living spaces, as well as new homes.

In conclusion, the Lennox Hearth HCI-36-H and RDI-36-H gas fireplaces epitomize the blend of design, technology, and efficiency. With features like customizable designs, advanced flame technology, and user-friendly operation, these models provide not just warmth, but a beautiful focal point that enhances any room. Whether you prioritize aesthetic or function, Lennox offers two exceptional options that cater to a variety of preferences.