Ventilation for
Gas and Electrical Connection
Vents
5.00 inch maximum
Not more than 5.00 inches from inside bottom of countertop.
5.00inch maximum
1.00inch maximum
Bottom Vent not
Gas Connection
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the grill rating plate agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas
Gas Conversion
To convert a grill from natural to LP/Propane or LP/Propane to natural, you MUST use conversion kit sold seperately.
CAUTION
Conversions should only be performed by an authorized service technician.
All vents no more than 5.00 inches above the floor of the installation.
more than 1.00 inch from inside floor of installation.
In Canada: Installation must be in accordance with the current
Electrical Connection
WARNING
ELECTRICAL SHOCK HAZARD
This appliance is equipped with a 3’ (91.4 cm)
Vents located on sidewall
An enclosure for an
a.One side of the enclosure shall be completely open; or
b.For an enclosure having four sides, a top and a bottom:
1.At least two ventilation openings (See Part IV, Definitions) shall be provided in the side walls of the enclosure, located within 5 in. (217 mm) of the top of the enclosure, equally sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s) shall have a total free area of not less than 1 in2/lb (1.42 cm2/kg) of stored fuel capacity.
2.Ventilation opening(s) shall be provided at floor level at rear of the enclosure and shall have a total free
area of not less than 1/2 in2/lb (7.1 cm2/kg) of stored fuel capacity. The bottom of the openings shall be 1 in. (25.4 mm) or less from the floor level and the upper edge no more than 5 in. (127 mm) above the floor level. The openings shall be equally sized, spaced at a minimum of 90 degrees (1.57 rad) and unobstructed.
3.Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2 mm) diameter rod.
4.Ventilation openings in the side walls shall not communicate directly with other enclosures of the outdoor cooking gas appliance.
Note: It is strongly recommended to follow the same ventilation requirements when using Natural Gas.
made by a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1/NFPA 54. The gas grill and its individual
plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug. This unit is not fused and installer must install a GFI. Unit must be grounded in accordance with local codes or with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
22 | 23 |