Viking viking manual Leak Testing

Page 15

Leak Testing

Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.

1

Do not smoke while leak testing.

Extinguish all flames.

Never leak test with an open flame

CAUTION

Before placing into operation, always check for gas leaks with a soapy water solution. DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS.

2

OFF

5

6

Bubbling bubbles in the soap solution indicates that a

Stop a leak by tightening the loose joint or by

leak is present.

replacing the faulty part with a replacement part

 

recommended by the manufacturer.

7

1

8

2

Make a soap solution of one part liquid detergent and

Check that all control knobs are in the “OFF” position.

one part water. You will need a spray bottle, brush or

 

 

 

 

 

towel to apply the solution to the fittings.

 

 

 

Note: For LP/Propane units, check with a full cylinder.

 

 

 

3

 

4

 

 

 

 

 

 

 

 

 

Apply the soap solution to fittings.

Turn cylinder valve knob counter clockwise one

 

turn to open.

Do not attempt to repair the cylinder valve if it should

If you are unable to stop a leak, shut off the gas

become damaged. The cylinder must be replaced.

at the cylinder valve. Remove the cylinder from the grill.

9

Call an authorized gas

appliance service technician or LP/Propane gas dealer.

Do not use the grill until

the leak is corrected.

OFF

2

1

After checking for leaks, push in and turn any control knob to release the pressure in the hose and manifold.

Turn off the control knob.

28

29

Image 15
Contents Viking Installation Guide Table of Contents 30W. & 36W and 300 Series Grills 30W & 42W 500 Series Grills 127 135 General Information 15/16 74 /2 80 /8 15/163 35-1/4 89.5cm Electrical connection Electrical Connection Regulator Assembly LP/Propane Tank Requirements LP/Propane Tank Connection Built-In InstallationsLeak Testing Off2 Burner AdjustmentFinal Preparation Rotisserie System Performance ChecklistViking Range Corporation Preferred Service Service & Registration
Related manuals
Manual 4 pages 5.36 Kb