Magma DM10-016LP owner manual Inspection for Spiders, Inspection Procedure

Page 8

INSPECTION FOR SPIDERS

Spiders, Earwigs, and other insects find the venturi tube and burner of barbeques to be ideal nest building areas. Webs, or the insects themselves, can block the flow of gas, which may cause flash- back (a fire in the venturi tube). Always inspect these areas prior to operation of the grill.

Inspection Procedure:

Igniter Electrode

1.

Be sure that the

4. Remove the grill

5. Remove the

6. Remove the burner by

2.

grill is cold.

grate by depressing

Radiant Plate

unscrewing it counter-

Be sure that

the grate at the

and Dome.

clockwise. Take care not

3.

gas is off.

tabs and turning

 

to damage the igniter

Open the lid.

the grate clockwise

 

electrode. Inspect the

 

 

until it is free of

 

burner at this time and

 

 

the holding clips.

 

clean as required.

B

A

7. Open the

8. Align the slot in

9. Visually inspect

Inspection Panel

the oriface (A) to

the venturi tube

on the rear of

the detent in the

for obstructions.

the column.

venturi tube (B).

 

 

Slide the hose free.

 

10.Clean the tube by running a small brush or similar cleaning item through the venturi tube

B

A

11. When the blockage has been

removed, align the slot in the ori- face (A) to the detent in the ven- turi tube (B). Insert the hose and rotate the orifice so that the slot faces outward.

Igniter Electrode and

burner ground strap

12. Replace the burner by screwing it clockwise

until snug on

to its threaded tube, Once again being careful not to damage the

igniter electrode. Insure that one of the two burner ground straps

is directly above the electrode.

13.Replace the radiant plate and dome and the grill grate.

8

Image 8
Contents N E R ’ S M a N U a L Important Safety Warnings Keep outdoor cooking gas appliance area clear 800 86 Magma Or e-mail us at mail@MagmaProducts.com Features No exposed tanks or wiresStainless steel double lined lid Easy Lift hinged lid All stainless steel constructionRemoving Packing Materials Clockwise from Inspection of HosesCounter Inspection Procedure Inspection for SpidersTighten Leak TestBe sure that the valve is in the off position Clockwise into Operation of the Hideaway Control PanelChanging the Fuel Canister Match Lighting Lighting InstructionsIgniter Lighting Operation Leveling the GrillUsing the DEL MAR AS a Stove Using the Del Mar as a StoveWord about Stainless Steel Maintaining Your GrillTrouble Shooting Guide Expanded View DEL MAR by Magma DEL MAR Accessories Other Magma AccessoriesStores in less Than 1/2 cubic footQuick Reference Chart Approximate Cooking Times and TemperaturesLimited Warranty