Leak Testing (20 lb. Refillable) IMPORTANT!
For your safety
•Leak test must be repeated each time LP tank is exchanged or refilled.
•Do not smoke during leak test.
•Do not use an open flame to check for gas leaks.
•Grill must be leak checked outdoors in
Use a clean paint brush and 50/50 soap and water solution. Use mild soap and water.
Do not use household cleaning agents. Damage to gas train components can result. Brush soapy solution onto the shaded areas shown below (A).
A
CAUTION
If “growing” bubbles appear do not use or move the LP tank. Contact an LP gas supplier or your fire department.
Connecting The Adapter Hose (sold separately) To The LP Tank
1. | Use only adapter hose approved by safety testing |
|
| organizations (CSA, UL, etc). | Off Clockwise |
2. | Turn all control knobs to the OFF position. |
|
3. | Turn LP tank OFF by turning |
|
| clockwise to a full stop. |
|
4. | Remove the protective cap from LP tank valve. |
|
| Always use cap and strap supplied with valve. |
|
(This section continued on next page.) |
|
OPD Hand Wheel
Type 1 outlet with thread on outside.
Safety relief valve
Use of this POL transport plug
(plastic part with external threads)
will defeat safety feature of valve.
Strap and cap