Compressor Fault
Warranty
Historic Diagnostics
Main Reports Settings
Suction Temperature Sensor
Safety
Keypad/Display Lockout Feature
Chiller Mode Stopped
Page 1
Image 1
User Guide
Tracer CH530™
Chiller Control System
CGWN/CCUN
205-211
CGAN
209-214
CG-SVU02B-E4
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
User Guide
General information
Safety recommendations
Foreword
Reception
Maintenance contract
Warranty
Training
Contents
Controls Interface
Overview
Display Screens
DynaView Interface
Keypad
Keypad/Display Lockout Feature
Main Screens
Main Reports Settings
Auto Stop
MP Resetting Sub Modes Description
Chiller Level Mode Top Level Mode Description MP Resetting
Chiller Level Mode Top Level Mode Description Stopped
Stopped Sub Modes Description
Chiller Level Mode Top Level Mode Description Auto
Chiller Level Mode Top Level Mode Description Run Inhibit
Run Inhibit Sub Modes Description
Auto Sub Modes Description
Chiller Level Mode Top Level Mode Description Running Limit
Chiller Level Mode Top Level Mode Description Running
Waiting to Start Sub Modes Description
Running Sub Modes Description
Chiller Level Mode Top Level Mode Description Misc
Chiller Level Mode Top Level Mode Description Shutting Down
Shutting Down Sub Modes Description
Misc. Sub Modes Description
Circuit Level Operating Modes
Circuit Level Mode Top Level Mode Description Shutting Down
Circuit Level Mode Top Level Mode Description Running Limit
Circuit Level Mode Top Level Mode Description Misc
Preparing Shutdown Sub Modes Description
Reports Screen
Ashrae Chiller Log
Historic Diagnostics
Circuit Ashrae Log
Description Units Resolution, Default Chiller
Settings Screen
System Manual Control Settings
Feature Settings
Circuit Manual Control Settings
Display Settings
Chiller Mode Stopped
Diagnostics Screen
CD-ROM
TechView Interface
Software Download
TechView Interface
Diagnostics
Modes Criteria Reset Inactive Level MP Reset Has Occurred
Active Diagnostic Name Effects Severity
Compressor Fault
Low Pressure Cutout
Temperature
Suction Temperature Sensor
Evaporator Entering Water
Temp Sensor Evaporator Leaving Water
High Evaporator Water
Error
High Pressure Cutout
Emergency Stop
Pump Fault Detected
Fault Detected
Pump 1 or Fan Fault
Evaporator Water
Active Criteria Reset Modes Level Inactive
Diagnostic Name Effects Severity
Diagnostics
Special
DynaView Display Message Description Troubleshooting
Main Processor Boot Messages and Diagnostics
Diagnostics
Default setting Event/Status
Programmable Relays Alarms and Status
Event/state Description
CG-SVU02B-E4
CG-SVU02B-E4
Top
Page
Image
Contents