Hold coupling nut and regulator as shown for proper connection to LP tank valve.
6.Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal on the
NOTE:
If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the connection, do not use this regulator!
WARNING
•Do not insert any foreign objects into the valve outlet. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.
•Never attempt to attach this grill to the
•Do not use grill until
•If a leak is detected at any time, STOP and call the fire department.
•If you cannot stop a gas leak, immediately close LP tank valve and call LP gas supplier or your fire department!
Leak Testing Valves, Hose and Regulator
1.Turn all grill control knobs to OFF.
2.Be sure regulator is tightly connected to LP tank.
3.Completely open LP tank valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.
4.Brush soapy solution onto areas circled below.
Rear view of grill.
5.If “growing” bubbles appear, there is a leak. Close LP tank valve immediately and retighten connections. If leaks cannot be stopped do not try to repair. Call for replacement parts. Order new parts by giving the serial, model number and name of items needed to the Grill Service Center at
6.Always close LP tank valve after performing leak test by turning hand wheel clockwise.
6 • 461644304