GE Monogram ZGG48N31CSS Combustible enclosures require insulated jackets, Clearances All Models

Page 2

Monogram.

ZGG48N31CSS - GE Monogram 48" Outdoor Cooking Center

Dimensions and Specifications (in inches)

 

 

If Installing

 

 

an Electrical

 

 

Outlet for

 

 

the Rotisserie

 

 

Motor, Mount

 

 

on Right Side

 

 

(6.5 AMP Min.)

3" Min. for Lid

51-3/4"

23-3/4"

Clearance

 

 

 

 

35-1/2"

 

18-1/2"

3-1/8"

 

 

10-1/8"

 

4x4 Opening

18-1/4"

for Gas Supply

 

Line

 

24-1/8"

Opening

 

 

for Access

 

 

Doors

 

 

If Installing

 

 

an Electrical

 

 

Outlet for

 

 

the Rotisserie

 

 

Motor, Mount

 

 

on Right Side

 

 

(6.5 AMP Min.)

3" Min. for Lid

45-3/4"

22-3/4"

Clearance

 

 

 

 

35-1/2"

 

18-1/2"

 

9-1/8"

 

4x4 Opening

18-1/4"

for Gas Supply

 

Line

 

24-1/8"

Opening

 

 

for Access

 

 

Doors

Installation in a combustible enclosure.

ZX48JYSS insulated jacket is required.

Combustible enclosures require insulated jackets.

ZX36JYSS for 36” models and ZX48JYSS for 48” models. The insulated jacket must be supported from the bottom by a solid deck or ledge on each side beneath the jacket.

Construct the enclosure as shown and place the insulated jacket into the enclosure. Place the cooking center into the jacket. No installation hardware is required.

Specification Revised 9/00

Installation in a non-combustible enclosure.

In a non-combustible (masonry) enclosure, the grill drops into the opening and hangs from its side flanges. A deck is not required for support.

Clearances - All Models

Allow 3” at the rear for lid clearance.

Allow at least 12” clearance at the back of the grill when exhaust is directed to a window or a surface that is difficult to clean.

Allow at least 6” clearance on each side to any non-combustible material located above the cooking surface for counterspace. Rotisserie models also require 6” clearance for placing and handling the motor and skewer.

Allow at least 12” clearance on each side to combustible vertical materials.

For answers to your Monogram,®

GE Profile Performance Series,

GE Profileor GE appliance questions, call

GE Answer Center® service, 800.626.2000.