Napoleon Fireplaces BGD42P manual Operation / Maintenance, Operating Instructions

Page 23

23

OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

than air and will settle on the floor

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or at- tempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

FOR YOUR SAFETY READ BEFORE LIGHTING:

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de- partment.

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocou- ple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed

WHAT TO DO IF YOU SMELL GAS

slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. IfGASyou smellKNOBgas including near the floor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.

5.Turn gas knob counter-clockwise to pilot.

6.Depress slightly and hold gas knob while lighting the

LIGHTING INSTRUCTIONS

pilot with the push button ignitor. Keep knob depressed Turn off the gas and electrical power before servicing

for one minute, then release. If pilot does not continue to

the fireplace.

burn, repeat steps 3 through 5.

CAUTION: Label all wires prior to disconnection when serv-

7.With pilot lit, depress and turn gas knob counter-clock- icing controls. Wiring errors can cause improper and dan-

wise

to on.

gerous operation. Verify proper operation after servicing.

8.If equipped with remote on-off switch/thermostat, This fireplace and its venting system should be inspected main burner may not come on when you turn valve to before use and at least annually by a qualified service on. Remote switch must be in the on position to ignite person. The fireplace area must be kept clear and free of

burner.

 

combustible materials, gasoline or other flammable va-

9.

Turn on all electric power to the fireplace.

pours and liquids. The flow of combustion and ventilation

air must not be obstructed.

1.

Turn off all electric power to the fireplace if service is

1. In order to properly clean the burner and pilot assem-

to be performed.

 

2.

Push in gas control knob slightly and turn clock-

 

wise

to off. Do not force.

 

TO TURN OFF GAS

bly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shut-

ter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

MAINTENANCE

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly.

4.Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and reaches to- ward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer / distributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary. Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.

W415-0381 / E / 02.09.06

Image 23
Contents Direct Vent Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information Venting Lengths VentingAIR Terminal Installations Special Vent Installations Typical Vent InstallationsHorizontal Termination Vertical Venting Application Flow ChartElbow Vent Length Values Horizontal TerminationDefinitions Formula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet Vertical Termination Example Formula 1 HT 3VT Formula 2 HT + VT 40 feet Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionVertically and plumb. Attach the air Using Flexible Vent ComponentsFireplace Vent Connection Using Rigid Vent ComponentsGAS Installation Vertical Venting InstallationFraming Mobile Home InstallationMantle Installation Nailing TAB InstallationPorcelain Reflective Panels GDL42 Louvre InstallationL42 Louvre Installation Logo Placement Finishing#2 #3 Charcoal Embers Charcoal Lumps Optional Blower InstallationGD36 Thermostatic Sensor Control Optional FAN InstallationOperating Instructions Operation / MaintenanceMaintenance Venturi Adjustment AdjustmentsPilot Burner Adjustment Accessories ReplacementsReplacement Parts W415-0381 / E Symptom Problem Test Solution Trouble Shooting GuideAfter Taking Pressure READINGS, be Sure to Turn
Related manuals
Manual 28 pages 35.93 Kb

BGD42P specifications

Napoleon Fireplaces has long been recognized for their commitment to quality, style, and innovation in home heating solutions. Among their impressive lineup, the BGD42P and BGD42N models stand out, showcasing exceptional features and advanced technologies that make them a popular choice for both aesthetics and functionality.

The BGD42P is a contemporary gas fireplace designed to provide a sleek, modern look for any living space. It features an impressive 42-inch viewing area, allowing for a magnificent fire display that becomes the focal point of any room. This model includes a high-efficiency burner, which not only produces a stunning flame but also ensures that the warmth is evenly distributed throughout the space. The BGD42P uses a direct vent system, providing safe and efficient venting, which eliminates the need for a traditional chimney and minimizes heat loss.

On the other hand, the BGD42N offers a more traditional appearance, making it an excellent choice for those who prefer classic design elements. Like its counterpart, it boasts a 42-inch viewing area and a high-efficiency burner. However, the BGD42N incorporates a realistic log set, enhancing its traditional appeal while still delivering exceptional heat output and efficiency. Both models are equipped with Napoleon's advanced electronic ignition system, ensuring quick and reliable starts even during power outages.

One of the standout technologies featured in both models is the proprietary PHAZER log set. This innovative design enhances the realism of the flame presentation, resembling a natural wood-burning fire. Additionally, Napoleon’s exclusive heat management system allows users to maximize comfort while minimizing energy consumption.

Both fireplaces come with customizable options, including a variety of decorative media such as river rocks or glass beads, allowing homeowners to personalize their space to match their unique style. Furthermore, Napoleon offers optional remote controls, making operation effortless.

In summary, the BGD42P and BGD42N models from Napoleon Fireplaces exemplify the company’s dedication to delivering high-quality, stylish, and efficient home heating solutions. With a blend of modern technology and classic design elements, these fireplaces not only provide warmth but also enhance the ambiance of any living area. Whether you lean towards contemporary or traditional aesthetics, Napoleon's offerings are sure to meet and exceed expectations, making them a worthwhile investment for any homeowner.