Quadra-Fire FG21SP-LP Maintaining and Servicing the Appliance, Maintenance and Service Tasks

Page 16

8 Maintaining and Servicing the Appliance

Although the frequency of appliance servicing and main- tenance will depend on use and the type of installation, a qualified service technician should perform an appliance check-up annually.

WARNING

Risk of injury or property damage

Before servicing:

Turn off utilities to appliance.

Ensure appliance is completely cooled.

WARNING

Annual inspection by qualified technician recommended.

Check:

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of burner assembly.

Burner ignition and operation.

Burner air shutter adjustment.

Gas connections and fittings.

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

Maintenance and Service Tasks:

Inspect

 

Maintenance Tasks

Burner Assembly

1

Remove logs and examine burner. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution

 

 

when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be

 

 

avoided.

 

 

 

 

2

Remove any foreign objects

 

 

 

 

3

Inspect for paint condition, warpage, corrosion. Sand and repaint as necessary.

 

4

Verify unobstructed air circulation.

 

 

 

Logs

1

Inspect for broken, damaged or missing logs. Replace as necessary.

 

2

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

 

 

3

Verify logs are clean and carbon (soot) free. Logs may be cleaned with a dry bristle brush or dry cloth.

 

 

Handle logs with care as they are fragile and easily damaged.

 

 

 

Burner ignition and operation

1

Verify all gas connections are tight and leak-free.

 

2

Clean off burner top corrosion or deterioration. Replace burner if necessary.

 

 

 

 

3

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

4

Inspect for lifting or other flame problems.

 

5

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

6

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

16

Quadra-Fire • Fogata Grande

October 2006

Image 16
Contents FG21SP-LP What to do if you smell gasCongratulations Listing Label Information/LocationTable of Contents Listing and Code Approvals BTU SpecificationsAppliance Certification Design and Installation Considerations Getting StartedTools and Supplies Needed Asphyxiation RiskValve Control Box Assembly Inspect the Appliance and ComponentsFraming and Clearances Select Appliance LocationClearances Fire RiskAppliance Set Up Quadra-Fire Fogata Grande Fuel Gas InformationGas Pressure High Altitude Installations Gas ConnectionPiezo On/Off Switch Operating InstructionsBefore Lighting Appliance Valve Control KnobTo Turn OFF GAS to Appliance After the Appliance is Lit Fire Risk High TemperaturesInspection Before Each Use Troubleshooting TroubleshootingMaintenance and Service Tasks Maintaining and Servicing the ApplianceRisk of injury or property damage Before servicing CheckReference Materials Service Parts List# Description of Part Part Number Qty Log Logs# Description of Part Part Number QtyLogs To obtain service under this warranty, you must
Related manuals
Manual 21 pages 5.23 Kb

FG21SP-NG, FG21SP-LP specifications

The Quadra-Fire FG21SP-LP and FG21SP-NG are innovative gas stoves designed to enhance heating efficiency while providing an aesthetic charm to any living space. These models epitomize the ideal blend of contemporary design, quality engineering, and reliable performance, making them popular choices among homeowners seeking an effective heating solution.

One of the main features of the FG21SP series is its versatile fuel options. The FG21SP-LP operates on propane, while the FG21SP-NG is designed for natural gas. This flexibility allows users to select the fuel type that best suits their preferences and needs, ensuring a seamless integration into existing home systems.

Both models are equipped with a powerful 21,000 BTU capacity, providing ample heat for medium to large spaces. This heating output ensures that rooms maintain a comfortable temperature efficiently, especially during the colder months. The adjustable flame height allows users to customize the ambiance and heat output easily.

The stoves feature a unique bay front design, which offers a stunning view of the flames while maximizing the overall heat radiated into the room. The large viewing area is enhanced by the ceramic glass door, which is not only stylish but also durable and resistant to high temperatures.

Efficiency is a significant attribute of both the FG21SP-LP and FG21SP-NG models. With a high efficiency of up to 82%, these stoves convert a large percentage of fuel into usable heat, minimizing waste and reducing energy costs over time.

One of the standout technologies employed in these stoves is the Quadra-Fire’s innovative heat management system. This system ensures effective heat distribution while maintaining a steady and reliable performance. Additionally, both models come equipped with a variable-speed blower that enhances heat circulation, optimizing comfort throughout the space.

Maintenance is made simple with the FG21SP series, thanks to features such as easy access to the interior for cleaning and inspections. The attractive design, combined with the robust construction and user-friendly features, sets the Quadra-Fire FG21SP-LP and FG21SP-NG apart from other gas stoves in the market.

In conclusion, the Quadra-Fire FG21SP-LP and FG21SP-NG gas stoves deliver on performance, efficiency, and aesthetic appeal, making them excellent choices for anyone looking to upgrade their home heating system. With their modern design and array of features, these stoves not only provide warmth but also serve as beautiful focal points in any room.