Sierra Products UV360FP For Your Safety Read Before Lighting, Lighting Instructions

Page 9

OPERATING INSTRUCTIONS FOR MANUAL SAFETY VALVE

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because

some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS;

MDo not try to light any appliance.

MDo not touch any electric switch; do not use any phone in your building.

MImmediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. M If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob, NEVER use tools. If the knob will not push in or turn by hand don't try to repair it, call a qualified service technician. Force or attempted repair may result in fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above before proceeding.

2.Push in gas control knob slightly and turn clockwise to "OFF".

NOTE: Knob cannot be turned unless pushed in slightly. Do not force.

3. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to next step.

4.Locate the pilot burner on the back side of burner.

5.Turn knob counter clockwise to Pilot. Push control knob all the way in and hold in, immediately lighting the pilot with a match. Continue to hold the control knob in for about 1-1/2 minutes after the pilot is lit. Release knob

and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 2 through 5.

M If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

M If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

6.Turn gas control knob counterclockwise to "HI".

FOR YOUR SAFETY, KEEP FIRE SCREENS CLOSED WHILE IN OPERATION .

TO TURN OFF APPLIANCE

1.Push in gas control knob slightly and turn clockwise to"OFF". Do not force.

2.Close access door.

9

Image 9
Contents Sierra UV36OFP Outdoor GAS Fireplace Installing General Safety ConcernsUnpacking Selecting Location Installation ClearancesMinimum Wall and Ceiling Clearances Clearances and projections front of fireplaceAttaching Optional Trim Installing GAS Piping to Fireplace Location BUILT-IN Fireplace InstallationInstallation Items Needed FramingExternal Regulator with Connecting Fireplace to GAS SupplyTest Pressures Equal to or Less Than ½ Psig Checking GAS ConnectionsCustomer SERVICE& Parts Replacement MaintenanceTrouble Shooting Operating Your NEW ApplianceFor Your Safety Read Before Lighting Lighting InstructionsTo Turn OFF Appliance Brooks St., Ste B Montclair, CA Fill out & return within 30 days