Sierra Products UV360FP BUILT-IN Fireplace Installation, Framing, Installation Items Needed

Page 5

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing a fireplace into a framed-in enclosure. This makes the front of the fireplace flush with the wall. Best outdoor enclosure construction includes metal stud with tile or concrete board as an overlay. Additions of ceramic tile and acrylic stucco finishes provide good service. To install the fireplace in this manner, use the following instructions:

Framing

1.Construct framing using dimensions, shown in figures 13 through 15, depending on your particular installation.

UV36OFP Fireplace

Actual

Framing

Height

32 3/8"

33"

 

 

 

Front Width

36"

36 ½"

 

 

 

Depth

18 ½"

19"

If the fireplace is to be installed directly on carpeting, tile (other than ceramic), or any combustible material other than wood flooring; the fireplace must be installed upon a metal or wood panel extending the full width and depth of the fireplace.

Fig. 9 - Rough Opening for Floor

Installation in Wall

If a raised platform is to be constructed, ceiling clearances must be maintained (refer to section on clearances, page 4).

If installing in a corner, use dimensions shown in figure 9 for the rough opening. The height is 33" which is the same as the wall openings, page 5.

2.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas piping to Fireplace Location, page 6.

Figure 10 - Rough opening for

Installing in Corner

3.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

4.Attach flexible gas line to fireplace gas valve. See Connecting Fireplace to Gas Supply, page 6.

5.Carefully insert fireplace into rough opening.

6.(Optional) Attach fireplace to framing using wood screws through holes located on interior sides of the fireplace (See Figure 11).

7.Check all gas connections for leaks. See Checking Gas Connections, page 6.

Figure 11 - Framing/Cabinet Mounting Holes

INSTALLING GAS PIPING TO

FIREPLACE LOCATION

NOTICE: A qualified person must connect fireplace to gas supply. Follow all local codes.

CAUTION: Never connect heater directly to the propane supply. This heater requires an external regulator(not supplied). Install the external regulator between the heater and propane supply.

Installation Items Needed

Before installing the fireplace, make sure you have the items listed below.

5

Image 5
Contents Sierra UV36OFP Outdoor GAS Fireplace Unpacking InstallingGeneral Safety Concerns Selecting Location Installation ClearancesMinimum Wall and Ceiling Clearances Clearances and projections front of fireplaceAttaching Optional Trim Installing GAS Piping to Fireplace Location BUILT-IN Fireplace InstallationInstallation Items Needed FramingExternal Regulator with Connecting Fireplace to GAS SupplyTest Pressures Equal to or Less Than ½ Psig Checking GAS ConnectionsCustomer SERVICE& Parts Replacement MaintenanceTrouble Shooting Operating Your NEW ApplianceTo Turn OFF Appliance For Your Safety Read Before LightingLighting Instructions Brooks St., Ste B Montclair, CA Fill out & return within 30 days