Leak Test Procedures

Leak Test Procedures

Create a mixture of equal parts soap and water. Apply to all the joints of the pipe fittings from the gas sup- ply pipe to the burner. Turn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a leak. Turn off the gas supply valve and tighten those fittings. Repeat the above procedure until no bubbles appear in the soap solution. Remember to test all joints.

WARNING: DO NOT USE AN OPEN FLAME TO TEST FOR LEAKS!

NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the gas supply line.

Remote Installation

Connect remote (GWSK or MRC 1, 2, 3) wires to ON/OFF/RS switch. (Fig. 8) If the MRC (remote) is used, the receiver can be placed to the front right of the gas valve to ensure safe operation.