Leak Test Procedures
Create a mixture of equal parts soap and water. Apply to all the joints of the pipe fittings from the gas sup- ply pipe to the burner. Turn on the gas supply valve for no longer than
WARNING: DO NOT USE AN OPEN FLAME TO TEST FOR LEAKS!
NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the gas supply line.
Remote Installation
Connect remote (GWSK or MRC 1, 2, 3) wires to ON/OFF/RS switch. (Fig. 8) If the MRC (remote) is used, the receiver can be placed to the front right of the gas valve to ensure safe operation.
Thermo Generator (“T(“Thermopile”)
Pilot
Assembly
TH TP TH/TP
FF
O
N
O
Remote
Switch
Figure 8
On/Off/Rs Switch
LG188