Technical Information

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or

property damage. Read these directions thoroughly before installation. For assistance or additional information, consult your gas log dealer, qualified installer, service agency or

gas supplier.

WARNING

Do not use this appliance or any part that has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

WARNING

Young children are not allowed to operate this unit and must be supervised when they are in the same room as the appliance.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.

WARNING

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. In addition, clothing or other flammable material should not be placed on or near the appli- ance.

WARNING

A properly sized, unobstructed chimney will normally vent all fumes and products of combustion. Any odor or smoke detected in the room is an indication that the flue is not properly removing the combustion products. Turn off the gas supply valve immediately! The cause of the venting problem must be discov- ered and corrected before using this gas log set. Disregarding this warning can cause illness as well as soot damage to your fireplace, room, and furnishings.

Technical Information

The operation of a gas log set, and the provision for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and applicable codes.

Gas Pressure Testing: This gas log set and its individual shut-off valve MUST be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPA). The gas log set must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa)

Component Parts: Only factory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority hav- ing jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items will void the manufacturer’s warranty, and may result in a hazardous condition.