Pre-Installation Checklist

Pre-Installation Checklist

Yes

No

Is the gas supply inlet pressure correct?

NG: Min. 5.5” w.c./Max. 14.0” w.c. LP: Min. 11” w.c./Max. 14.0” w.c.

Does the firebox meet the minimum size dimensions below?

Is your fireplace plumbed with gas on the right side (facing) of the fireplace?

If not, refer to ee Page 5

Is the gas supply line sized properly (Minimum 1/2” iron pipe)?

Do you have a solid fuel (wood burning) fireplace with a vented flue?

Do you have a manual gas supply valve installed at your fireplace? If not, a licensed plumber, gas company technician or other qualified installer must install one.

Have you checked local building codes? (Check with your local building department)

Does your fireplace have a wire mesh screen in place?

CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance.

 

 

 

 

Minimum Clearances & Specifications

 

 

 

 

 

 

 

Natural Gas Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Firebox Dimensions

Minimum

Gas Fuel Line

Manifold

Set

Input

 

 

 

 

 

Flue

Pressure

Pressure

 

Width

 

 

Size

Btu/hr

Back

 

Front

Depth

Height

Size

Minimum

Maximum”

 

18”

45,000

16”

 

33”

15”

18”

51 sq.in.

5.5”w.c.

14.0”w.c.

3.5”w.c.

24”

60,000

20”

 

36”

15”

18”

51 sq.in.

5.5”w.c.

14.0”w.c.

3.5”w.c.

30”

60,000

27”

 

39”

15”

18”

51 sq.in.

5.5”w.c.

14.0”w.c.

3.5”w.c.

 

 

 

 

 

 

 

 

 

 

 

NOTE: All dimensions are minimums.

Propane Gas Units

 

 

Minimum Firebox Dimensions

Minimum

Gas Fuel Line

Manifold

Set

Input

 

 

 

 

 

Flue

Pressure

Pressure

 

Width

 

 

Size

Btu/hr

Back

 

Front

Depth

Height

Size

Minimum

Maximum

 

 

18”

40,000

16”

 

33”

15”

18”

51 sq.in.

11.0”w.c.

14.0”w.c.

10.0”w.c.

 

24”

45,000

20”

 

36”

15”

18”

51 sq.in.

11.0”w.c.

14.0”w.c.

10.0”w.c.

 

30”

60,000

27”

 

39”

15”

18”

51 sq.in.

11.0”w.c.

14.0”w.c.

10.0”w.c.

NOTE: All dimensions are minimums.