Napoleon Grills 600RB manual Leak Testing Instructions, Regulator

Page 5

LEAK TESTING INSTRUCTIONS

DO NOT USE A FLAME TO LEAK TEST.

LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No smoking while performing this test, and remove all sources of ignition. See Leak Testing Diagram for areas to check.

1.Turn all burners controls to off. Turn supply valve on.

2.Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.

3.Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.

4.If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer. Do not use the appliance until the leak has been corrected.

5.Turn off gas supply.

REGULATOR

The following table lists input values for the appliance.

BURNER

ORIFICE SIZE

HEAT INPUT

GAS USAGE (TOTAL)

 

I

II

(TOTAL)

PROPANE

BUTANE

MAIN

63

65

16.4 kW

1173 g/h

1192 g/h

BACK

56

59

7.6 kW

543 g/h

553 g/h

SIDE

60

64

4.5 kW

322 g/h

327 g/h

Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.

Gas Category

I3B/P(30)

I3+(28-30/37)

I3B/P(50)

Orifice Sizes (see above)

I

I

II

Gases / Pressures

Butane 30mbar

Butane 28-30mbar

Butane 50mbar

 

Propane 30mbar

Propane 37mbar

Propane 50mbar

 

 

 

 

Countries

DK, FI, NL, NO,

BE, ES, FR, GB,

DE, AT

 

SE

IE, IT, PT

 

The regulators for both butane and propane must have a rating of at least 1500 g/h. Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table above.

5

Image 5
Contents Prestige 600/600RB Conditions and Limitations Napoleon GAS Grill Presidents Limited Lifetime WarrantyDOS Donts Safe Operating PracticesGAS Hose GAS CylinderRegulator Leak Testing InstructionsOpen lid Lighting InstructionsCooking Instructions Cleaning InstructionsTroubleshooting Maintenance InstructionsOrdering Replacement Parts Conditions ET Limitations Garantie À VIE Limitée DU PrésidentConsignes DE Sécurité AvertissementTuyau DE GAZ Bonbonne DE GAZUtilisez PAS DE Sources DE FEU Pour Verifer UNE Fuites Test DE Détection DE FuitesRégulateur Ouvrez le couvercle Instruction D’ALLUMAGENettoyage Instructions D’OPÉRATIONPointe Jaune Bleue Foncée Instructions D’ENTRETIENVis Guide DE DépannageCommande DES Pièces DE Rechange Voorwaarden EN Beperkingen WEL Niet WaarschuwingGasslang GasflesRegelaar Instructies I.V.M. LektestOpen het deksel Instructies I.V.M. AanstekenReinigingsinstructies KookinstructiesGele Uiteinden Donkerblauw Ongeveer OnderhoudsinstructiesProbleem Mogelijke oorzaken Oplossing ProbleemoplossingBestellen VAN Reserveonderdelen N570-0026 #14 X 1/2 Prestige N570-0026 #14 X 1/2 N570-0076 #8 X 1/2 N570-0026 #14 X 1/2 N305-0027 N520-0019 N305-0046 Page Description P600RB Description P600RB Page Customer Name Date Address Model Serial Telephone