Golden Technologies 18" - 24" & 30 For Your Safety Read Before Lighting, Lighting Instructions

Page 7

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance is equipped with a push-button piezo ignition device which automatically lights the pilot. If the piezo fails to ignite the pilot, then follow the lighting instructions for lighting the pilot with a match.

B. BEFORE LIGHTING smell all around the appliance for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance

Do not touch any electrical switch. Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information previously listed above.

2.Push in gas control knob slightly and turn clockwise to the OFF position.

NOTE: Knob cannot be turned from PILOT to OFF unless knob is pushed slightly. Do not force.

3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! follow “B” in the safety information listed above. If you don’t smell gas, go to the next step.

4.Find Pilot - follow metal tube from gas control. The pilot is located on the front side of burner in the center.

5.Turn knob on gas control counterclockwise to the PILOT position.

Push in control knob all the way and hold in. While still holding the control knob, press in the ignitor pushbutton several times. This will cause a spark at the pilot burner which will ignite the pilot flame. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release the knob and it will pop back out. Pilot should remain lit. If it goes out, repeat steps 1-5.

If knob does not pop out when released, stop and immediately call your service technician or gas supplier. If pilot does not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier.

6. Turn the gas control knob counterclockwise to ON.

NOTE: The gas control knob has two settings. With the gas control knob all the way to the ON position, the log is set on high, and with the control knob approximately half way between PILOT and ON the unit is on low. You can see the difference in the flame height.

TO TURN OFF GAS TO APPLIANCE

Push in gas control knob slightly and turn clockwise

to OFF. Do not force.

IGNITOR

 

PILOT BURNER

 

GAS CONTROL KNOB

 

 

IGNITOR

 

 

7

Image 7
Contents Installation and Operating Instructions Safety and General Information Golden Blount VENT-FREE LOG SET Component Parts GB-TFII-18 Burner System InstallationPlacement of Logs 18 Sets Placement of Logs 24 & 30 Sets Lighting Instructions For Your Safety Read Before LightingTo Turn OFF GAS to Appliance Lighting Instructions Millivolt Valve Shutting OFF Heater To Turn OFF GAS to Appliance Millivolt ValveQuantity Description Parts ListSymptom Possible Causes Corrective Action Troubleshooting Reference