Empire Comfort Systems CHG, CHR installation instructions Chg/Chr

Page 7

Figure 8

10.Place the hold-down bar under the flicker shield. Push the flicker shield and hold-down bar up to the bottom of the outdoor gas fireplace.

Figure 9

11.Insert the 4 5/8" hold down bolt through the hole in hold down bar and flicker shield and rear burner cross support. Secure with 5/16" nut from inside of firebox.

Figure 9

12.Move the outdoor gas fireplace to its permanent location. Follow installation instructions to determine the proper distances to adjacent combustible materials. Adequate room must be left behind the outdoor gas fireplace for the LP tank and to the left side for access to the control panel.

Figure 10

13.Install the three cast iron logs. Install the diagonal center bottom (#1) log first. Holes in (#1) log are to be positioned closer to front of burner assembly. Add the left cross (#3) log and then the right cross (#2) log. Recesses, tabs and holes are provided to locate the logs properly. See Figure 10 for proper placement. Installation of logs is completed.

Figure 10

Refer to the following warning.

Warning: Failure to position the parts in accordance with this photograph or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

Figure 11

14.Attach the 20 lb. LP tank support hook to the hole located in the rear center of the outdoor gas fireplace firebox wall. This hole is approximately 18" from the floor. Use the bolt, washer and nut provided and tighten by reaching into the firebox.

Figure 11

15.Set the LP tank in place. The gas outlet fitting on the tank should be facing toward the left when viewed from the front. The alternate is to face the outlet connection toward the rear. Lift the tank slightly and hook onto the tank support hook. One of the holes in the tank handle will fit over the hook.

16.Connect the QCC-1 fitting on the regulator hose to the fitting on the tank and tighten securely by hand.

CHG/CHR

Page 7

Image 7
Contents Outdoor GAS Fireplace Installation InstructionsImportant Warnings Table of ContentsInstructions to Installer SpecificationsOverfill Protection Device OPD on 20 LB. Propane Cylinder Minimum Clearances From Combustible Construction Figures 2 ClearancesFigures 6 SET-UP InstructionsCHG/CHR GAS Conversion Instructions GAS Pressure Leak TestingDo not Smoke While Leak Testing Lighting InstructionsAdjusting for Proper Flame Maintenance and ServiceBurner Maintenance and Cleaning Low heat with control knob set on HI TROUBLE-SHOOTINGHOW to Order Repair Parts