FIREPLACE INSTALLATION

Removing/Replacing Glass Door (Cont.)

Installing Optional Brick Liner Models BL36D(S) and BL36DH(S)

FIREPLACE INSTALLATION

Continued

Removing Glass Doors

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 42).

3.While holding glass door to prevent it from falling and caus- ing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 42).

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 42).

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under Removing Louver Panels, page 21.

Cleaning Glass Door

See Cleaning and Maintenance on page 27.

Latch Unlock Lock

Screw

Hinge

Glass Frame

Assembly

Figure 42 - Removing/Replacing Glass Door

INSTALLING BRICK LINER MODELS BL36DA(SA) AND BL36DHA(SA)

WARNING: If fireplace has been running, turn off unit. Let cool before installing brick liner.

You may purchase brick liner from your local retailer or see Accessories, page 36.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Exces- sive force will break brick panels.

1.Remove top and bottom louvers to allow access to door latches.

2.Unlock door latches and open glass door. See Removing/Re- placing Glass Door, steps 1 and 2.

3.If installing brick liner in new fireplace, go to step 4. If install- ing brick liner in an existing fireplace, carefully remove logs, lava rock, and ember material.

4.Remove three screws from deflector shield on the inside top of firebox. Set shield and screws aside.

5.Install rear brick panel first. Rest bottom edge of panel on back edge of burner assembly (see Figure 43).

6.Install left side brick panel by sliding it between the burner assembly and the side of the firebox (see Figure 43).

7.Install the right brick panel using the same method described

8.Replace deflector shield using screws removed in step 4.

9.Follow instructions to install logs, lava rock, and ember material.

10.Close glass door and lock latches on top and bottom of door and replace screen. See Removing/Replacing Glass Door, steps 5 and 6.

11.Close top and bottom louvers.

Left Side

Brick Panel

Rear Brick

Panel

Figure 43 - Installing Rear Brick Panel

For..com

111923-01A

Image 22
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Ground Floor InstallationCorner Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingModel BK Installation Fireplace InstallationInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsInstalling Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverRemoving Louver Panels Cleaning Glass Door Installing Brick Liner Models BL36DASA and BL36DHASARemoving Glass Doors For Your Safety Read Before Lighting Installing LOGS, Lava Rock and Glowing EmbersOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Optional HAND-HELD Remote OperationSafety Features Manual ModeAuto Thermostatic Mode ON/OFF Series Model GhrcbInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown ModelsParts List KEY Part Number Description QTYBurner Assembly for Models VK36N, VK36NH, VK36P, VK36PH Parts List Accessories Owners Registration Form Postage Required 111923-01A Warranty Information