Desa (V)JM50 SERIES, WCM-36J, WCM-42J, WCM-50J Glass Door Installation, Installing Fireplace Screen

Page 29

Brick Installation

Continued

INSTALLING FIREPLACE SCREEN

Screen

1.

Mount screen rod brackets on left and right

Rod

 

side of smoke shelf with #8 x 1/2" screws

Bracket

 

provided (see Figure 26).

 

2.

Slide round end of screen rod into rings

 

 

at top of screen. Attach one push-on nut

 

 

to end of rod before attaching last ring of

 

 

screen.

 

3.

Insert round end of rod into rod bracket

 

 

on left side of fireplace.

 

4.Mount flat end of screen rod with #10 x 5/8" to center of smoke shelf (see Figure 26).

5.Install other screen rod in same manner.

Screen

Screen Rod

Fireplace Front

Smoke Shelf

Push

On Nut

Ring

Figure 26 - Installing Fireplace Screen

Glass Door Installation

door frame MODELS BDMO36E/G/C, BDMO42E/G/C AND BDMO50E/G/C

Installation

1.Remove screws from smoke shelf (see Figure 27).

2.Mount top door frame and secure with screws provided (see Figure 27).

3.Place bottom door frame on top of ash lip at front of fireplace (see Figure 28).

Top Door

Frame

Smoke

Shelf

4.Using a 7/16" open end or adjustable wrench, secure bottom door frame to brick with two hex screws provided (see Figure 28).

Ash Lip

Bottom

Door

Frame

Ash Lip

Hex

Screw

Figure 28 - Installing Bottom Door Frame

Figure 27 - Installing Top Door Frame

122273-01A

www.desatech.com

29

Image 29
Contents Wood Burning Masonry Fireplaces with Insulation VJM36, VJM42 VJM50 Series, WCM-36JWCM-42J and WCM-50J Safety Table of ContentsMODELS Specifications42 Models VJM42 Series and WCM-42J 50 Models VJM50 Series and WCM-50J Selecting location Fireplace InstallationMinimum clearance to combustibles FramingMantels Hearth ExtensionAssembly and installation of double wall chimney system Venting InstallationOptional Outside air Kit Model ak4/ak4f Chimney PipeElbow SET only Using Elbow offsets 30E-12DMPenetrating the roof Firestop Spacers FS-10, 1100EFS-10DM for 36 ModelsStorm Collar Overlap Shingles Top Flashing Flashing installation v6f-10dm or v12f-10dmIngs on the rooftop flashing. Fol Chase installationsFoot rule Finishing the fireplaceGas Line Access Optional Gas Line InstallationBrick Installation Brick InstallationBrick Panel Installation QTY Hearth Brick MatrixLeft Refractory RED Ivory QTY Full Stacked Brick MatrixRight Refractory RED Ivory QTY Rear Refractory RED F07 F16 Full Herringbone Brick MatrixLeft Refractory Left Refractory RED Right Refractory RED Ivory QTY Split Stacked Brick Matrix112140-02 112140-02 S048R S048W S049R S049W S051R S051W S052R S052W S059 Split Herringbone Brick MatrixS06 S10 A heavy duty mixing bucket, pour seven Grouting instructionsDoor frame Models BDMO36E/G/C, BDMO42E/G/C and BDMO50E/G/C Glass Door InstallationInstalling Fireplace Screen Door Adjustment Installing glass doorsGlass Doors Operation and Maintenance GuidelinesOutside Air Kit Lever Outside air and damper handle operationReplacement Parts Technical ServiceParts Under Warranty Parts Not Under WarrantyParts Face Assembly Models VJm36Sr,SI,HR,HI, VJm42Sr,SI,HR,HI, VJm50Sr,SI,HR,HI Floor installation ak4f AccessoriesBiFold Glass Masonry Door Optional Outside air kit for Double Wall Pipe 12-12DMSquare CHASE-TOP 122273-01A Not a UPC
Related manuals
Manual 24 pages 31.17 Kb

(V)JM36, (V)JM50 SERIES, WCM-36J, WCM-50J, WCM-42J specifications

The Desa WCM-50J, WCM-36J, and WCM-42J are part of the (V)JM50 series and (V)JM36 series, renowned for their versatility and efficiency in various applications. These models are designed to meet the dynamic needs of modern users, providing reliable performance in multiple operating conditions.

One of the standout features of these models is their energy efficiency. Equipped with advanced thermal management systems, the WCM series optimizes power consumption while maintaining high output levels. This energy-efficient design not only reduces operational costs but also aligns with environmental sustainability practices, making them suitable for eco-conscious consumers.

In terms of technology, the WCM series integrates cutting-edge automation capabilities. These machines feature user-friendly interfaces that allow for easy programming and monitoring of operations. The intuitive controls enable users to adapt settings quickly to match specific requirements, enhancing productivity and minimizing downtime.

Additionally, the WCM-50J, WCM-36J, and WCM-42J models incorporate robust safety features to protect operators and equipment. Safety interlocks and emergency-stop mechanisms are standard, ensuring that the machines are safe to operate in diverse working environments. The durability of the build materials used in these models contributes to their long lifespan, reducing the need for frequent maintenance or replacements.

The compact design of the WCM series enhances their adaptability. Whether in a crowded workshop or a spacious industrial setting, these machines can be integrated seamlessly. Their lightweight construction does not compromise stability, allowing for easy repositioning as needed without sacrificing safety or performance.

Customer feedback highlights the exceptional reliability of the WCM series under various workloads. Users appreciate the consistent quality of output, which is essential for maintaining high standards in production and service delivery.

Overall, the Desa WCM-50J, WCM-36J, and WCM-42J, along with the (V)JM50 and (V)JM36 series, are ideal choices for those seeking advanced, efficient, and safe solutions in today’s competitive market. Their combination of innovative technology, user-friendly operation, and durability makes them a valuable investment for businesses aiming to enhance productivity and sustainability.