Desa (V)JM50 SERIES, WCM-36J, WCM-42J, WCM-50J, (V)JM36 Brick Installation, Brick Panel Installation

Page 14

Brick Installation

Brick Panel Installation

IMPORTANT: Installation of brick should be done after the fire- place is placed in a permanent location.

The brick housings are already installed on the panels. When installing brick housing panels into fireplace, wear gloves as edges may be sharp.

1.Beginning with left side panel, place panel, bottom edge first, at an angle into fireplace. Secure to bottom of fireplace with screws provided.

2.Install right side as left side in step 1 using screws provided.

3.Install back panel and secure back to sides and bottom of firebox with screws provided.

4.Using self-tapping screws and a drill, place screws into large holes in back and side panels (see Parts, page 34), through wire mesh and into firebox wrapper to secure.

Hole in

Side Panel

Figure 23 - Hole in Side Panel to Attach

to Firebox Wrapper

Brick Installation

Each brick housing is stamped with a number (full size bricks are not stamped). These num- bers will help identify the brick when installing. It is important to install these bricks exactly as instructed. Press brick firmly into brick housing until it snaps. Groove line on side of brick will come in contact with flange on the brick hous- ing. This secures brick into housing (see Figure 24). Smaller bricks may require a small portion of furnace cement applied to back of brick to secure it until grouting has been completed.

Bricks are packaged in separate boxes. The brick matrixes on pages 15 through 27 show how bricks are packaged and placed for each size fireplace and the number of bricks per box. There are 2 extra full bricks included in Hearth Brick package.

Install bricks one section at a time starting with hearth panel followed by the rear panel, left panel and right panel. It is important to install the bricks in sequence. Please note, full size bricks are NOT stamped.

Stamped

Brick Letter

Location

Flanges

Brick Housing

Figure 24 - Installing Brick

14

www.desatech.com

122273-01A

Image 14
Contents Wood Burning Masonry Fireplaces with Insulation VJM36, VJM42 VJM50 Series, WCM-36JWCM-42J and WCM-50J Table of Contents SafetySpecifications MODELS42 Models VJM42 Series and WCM-42J 50 Models VJM50 Series and WCM-50J Minimum clearance to combustibles Fireplace InstallationSelecting location FramingHearth Extension MantelsOptional Outside air Kit Model ak4/ak4f Venting InstallationAssembly and installation of double wall chimney system Chimney PipeUsing Elbow offsets 30E-12DM Elbow SET onlyFirestop Spacers FS-10, 1100EFS-10DM for 36 Models Penetrating the roofFlashing installation v6f-10dm or v12f-10dm Storm Collar Overlap Shingles Top FlashingFoot rule Chase installationsIngs on the rooftop flashing. Fol Finishing the fireplaceOptional Gas Line Installation Gas Line AccessBrick Installation Brick InstallationBrick Panel Installation Hearth Brick Matrix QTYFull Stacked Brick Matrix Left Refractory RED Ivory QTYRight Refractory RED Ivory QTY Rear Refractory RED Full Herringbone Brick Matrix F07 F16Left Refractory Left Refractory RED Split Stacked Brick Matrix Right Refractory RED Ivory QTY112140-02 112140-02 S048R S048W S049R S049W S051R S051W S052R S052W Split Herringbone Brick Matrix S059S06 S10 Grouting instructions A heavy duty mixing bucket, pour sevenDoor frame Models BDMO36E/G/C, BDMO42E/G/C and BDMO50E/G/C Glass Door InstallationInstalling Fireplace Screen Installing glass doors Door AdjustmentOperation and Maintenance Guidelines Glass DoorsOutside air and damper handle operation Outside Air Kit LeverParts Under Warranty Technical ServiceReplacement Parts Parts Not Under WarrantyParts Face Assembly Models VJm36Sr,SI,HR,HI, VJm42Sr,SI,HR,HI, VJm50Sr,SI,HR,HI BiFold Glass Masonry Door Optional Outside air kit for AccessoriesFloor installation ak4f Double Wall Pipe 12-12DMSquare CHASE-TOP 122273-01A Not a UPC
Related manuals
Manual 24 pages 31.17 Kb

(V)JM36, (V)JM50 SERIES, WCM-36J, WCM-50J, WCM-42J specifications

The Desa WCM-50J, WCM-36J, and WCM-42J are part of the (V)JM50 series and (V)JM36 series, renowned for their versatility and efficiency in various applications. These models are designed to meet the dynamic needs of modern users, providing reliable performance in multiple operating conditions.

One of the standout features of these models is their energy efficiency. Equipped with advanced thermal management systems, the WCM series optimizes power consumption while maintaining high output levels. This energy-efficient design not only reduces operational costs but also aligns with environmental sustainability practices, making them suitable for eco-conscious consumers.

In terms of technology, the WCM series integrates cutting-edge automation capabilities. These machines feature user-friendly interfaces that allow for easy programming and monitoring of operations. The intuitive controls enable users to adapt settings quickly to match specific requirements, enhancing productivity and minimizing downtime.

Additionally, the WCM-50J, WCM-36J, and WCM-42J models incorporate robust safety features to protect operators and equipment. Safety interlocks and emergency-stop mechanisms are standard, ensuring that the machines are safe to operate in diverse working environments. The durability of the build materials used in these models contributes to their long lifespan, reducing the need for frequent maintenance or replacements.

The compact design of the WCM series enhances their adaptability. Whether in a crowded workshop or a spacious industrial setting, these machines can be integrated seamlessly. Their lightweight construction does not compromise stability, allowing for easy repositioning as needed without sacrificing safety or performance.

Customer feedback highlights the exceptional reliability of the WCM series under various workloads. Users appreciate the consistent quality of output, which is essential for maintaining high standards in production and service delivery.

Overall, the Desa WCM-50J, WCM-36J, and WCM-42J, along with the (V)JM50 and (V)JM36 series, are ideal choices for those seeking advanced, efficient, and safe solutions in today’s competitive market. Their combination of innovative technology, user-friendly operation, and durability makes them a valuable investment for businesses aiming to enhance productivity and sustainability.