Desa (V)3612ST Fireplace Installation, Selecting Location, Mantel Clearances

Page 4

4

FIREPLACE INSTALLATION

Selecting Location

Clearances

Mantle Clearances

FIREPLACE INSTALLATION

SELECTING LOCATION

To determine the safest and most efficient location for your fire- place, you must take into consideration the following guidelines:

1.The location must allow for all the proper clearances (see Fig- ure 2).

2.Consider a location where the heat output would not be af- fected by drafts, air conditioning ducts, windows or doors.

3.A location that avoids the cutting of joists or roof rafters will make installation easier.

4.If an outside air kit is to be installed, accessibility to outside combustion air must be considered. This can also be achieved through a vented crawl space in some cases, for more details refer to the section on outside air kit installation.

The typical installation for a (V)3612ST is a projected installation, which allows you to extend the fireplace any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.

CLEARANCES

MINIMUM CLEARANCES TO COMBUSTIBLES

Back

1/2" Min.

Adjacent Wall

12" Min.

Chimney Outer Pipe Surfaces

2" Min.

Bottom Of Fireplaces To Floor

0" Min.

CAUTION: Do not block required air spaces with insulation or any other material. Do not obstruct effective opening of fireplace with any type of facing material. Combustible material must not be in con- tact with the black front face of the fireplace.

Figure 2 - Plan View of Common LocationFigure 3 - Fireplace Clearances

MANTEL CLEARANCES

Woodwork, such as wood trims, mantles, and other combustible materials, should not be placed within 9 inches of the effective opening of this fireplace.

Combustible material above and projecting more than 1 1/2 inches from the fireplace’s front face (see Figure 4, page 5), should not be placed less than 12 inches from the effective opening of the fireplace (Ref: NFPA std.7-3.3.3.).

Mantles or any other combustible material may also come up to the side edge of the black metal face of the fireplace, but only if the projection from the front face falls within the limits shown in Figure 5, page 5.

For morevisit www..com

115603-01A

Image 4
Contents For Your Safety Save this BookTable of Contents Product DimensionsSafety Information Introduction Before YOU BeginFireplace Installation Selecting LocationClearances Mantel ClearancesFraming Mantel ClearancesHearth Extensions 7cmOutside AIR KIT Installation GAS Line InstallationVenting Installation Pipe InstallationElbow Offset Installation Venting InstalltionSupport Sections Finishing Your Chimney System Foot RuleMinimum Chimney Height Maximum Chimney HeightChimney Maintenance Roof Opening ChartStorm Collar Installation Flashing InstallationTerminations Installing Fireplace Facing Chase InstallationCleaning the Glass Operating Guidelines and Maintenance InstructionsGlass Doors Technical Service Damper MechanismOutside AIR Mechanism GrateReplacement and Accessory Parts Owners Registration Form Postage Required 115603-01A Not a UPC

(V)3612ST specifications

Desa (V)3612ST is an advanced electronic device designed to enhance heating and ventilation systems in both residential and commercial settings. It combines state-of-the-art technology with user-friendly features, making it an ideal solution for those seeking efficiency and comfort in their environments.

One of the standout features of the Desa (V)3612ST is its variable speed motor, which allows for adjustable airflow. This technology enables users to customize their heating or cooling experiences based on personal preferences or external weather conditions. The variable speed capability also results in quieter operation, ensuring a more peaceful atmosphere.

The Desa (V)3612ST is equipped with a digital display that provides real-time information about temperature settings and system performance. This display is intuitive and user-friendly, allowing for easy adjustments to settings without the need for complex navigation. The inclusion of smart thermostatic controls further enhances functionality, enabling remote monitoring and control via mobile applications. This means that users can adjust their heating or cooling systems even when they are not at home, contributing to energy savings and convenience.

In terms of safety, the Desa (V)3612ST incorporates several features designed to protect users and property. An automatic shut-off function prevents overheating, while built-in sensors monitor air quality and system performance, alerting users to potential issues before they escalate. This adds an extra layer of reliability and peace of mind.

Energy efficiency is another key characteristic of the Desa (V)3612ST. It meets or exceeds the latest energy efficiency standards, helping users to lower their utility bills while minimizing their environmental impact. The device’s design promotes optimal airflow and heat distribution, ensuring that energy is used effectively.

In conclusion, the Desa (V)3612ST stands out for its innovative technology, user-friendly features, and commitment to safety and energy efficiency. Its variable speed motor, digital display, smart controls, and safety measures make it a versatile choice for anyone looking to improve their heating and ventilation systems. Whether used in homes or businesses, the Desa (V)3612ST delivers reliable performance and enhances overall comfort.