Desa VC42N, VC42P Replacement Parts, Service Hints, Technical Service, Specifications

Page 37

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service Department at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral infor- mation.

When calling DESA, have ready

model number of your fireplace

the replacement part number

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply might be low (propane/ LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

Technical Service

You may have further questions about installation, operation or troubleshooting. If so, contact DESA’s Customer Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

YoucanalsovisitDESA’stechnicalservicewebsiteat www.desatech.com.

Specifications

VC42N, VVC42N AND CGCDV42NR

• Rating: 25,000/36,000 Btu/hr

• Gas Type: Natural Gas Only

• Ignition: Piezo

• Manifold Pressure: 3.5" w.c.

• Minimum Inlet Supply Pressure: 5.5" w.c.

• Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 40" x 48" x 23 1/2" (1016 x 1219 x 599 mm)

VC42P, VVC42P AND CGCDV42PR

• Rating: 23,000/33,000 Btu/hr

• Gas Type: Propane/LP Gas Only

• Ignition: Piezo

• Manifold Pressure: 10.0" w.c.

• Minimum Inlet Supply Pressure: 11.0" w.c.

• Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 40" x 48" x 23 1/2" (1016 x 1219 x 599 mm)

VC42N-HA, VVC42N-HA AND

CGCDV42NR-HA

• Rating: 25,000/36,000 Btu/hr

• Gas Type: Natural Gas Only

• Ignition: Piezo

• Manifold Pressure: 3.8" w.c.

• Minimum Inlet Supply Pressure: 5.5" w.c.

• Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 40" x 48" x 23 1/2" (1016 x 1219 x 599 mm)

116236-01F

www.desatech.com

37

Image 37
Contents What to do if YOU Smell GAS Table of Contents Safety Information High traffic areas Product IdentificationPre-Installation Preparation Product FeaturesLocal Codes Location and space requirements42 1067 mm ClearancesFront 36 914 mm Top of Standoffs Vent See venting Venting clearancesNoncombustible mantels at any height above Framing and finishingFireplace Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Plug in blower power cordBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsClose equipment shutoff valve see Figure Disconnect fireplace and its individual equipPressure Testing Fireplace Gas Connections Installing optional wall Mount Switch gwmS2Installing Remote Receiver Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing Louver Panels Removing/Replacing Glass DoorRemoving Glass Door Installing Brick liner Models BL42DASA and BL42DHASA Installing lava rock and glowing embersCleaning Glass Door Operating Fireplace For your safety Read before lightingLighting Instructions Close top and bottom louversTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 On/Off Series Model HRC100Pilot assembly Operating optional blower accessoryKey Pad Lock Feature Inspecting BurnersBurner Flame Pattern Cleaning MaintenanceGlass Door Logs Pilot and burnersVenting system Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused byAfter pilot lights, keep gas Long enough Control knob pressedOr shut off Service person Remote does not function When burner is lit HI position when burner isTery power is low Cold Minute Air in gas line Operate burner until air isStatement above Service Hints Replacement PartsTechnical Service SpecificationsModels VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Illustrated Parts BreakdownParts List 19 18 Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownKeep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

CGCDV42NR, CGCDV42PR, VC42N, VC42P, VC42N, VC42P specifications

Desa offers a variety of versatile gas fireplaces, notably the VC42P, VC42N, CGCDV42NR, CGCDV42PR, and VC42N model lines. These fireplaces are designed to enhance home comfort and aesthetic appeal, marrying efficient heating technology with elegant design.

The VC42P and VC42N models are known for their powerful heating capabilities and stylish appearances. The ‘P’ in VC42P refers to its propane fuel option, ideal for homes not connected to natural gas lines. In contrast, the VC42N operates on natural gas, ensuring flexibility for homeowners based on their local fuel availability. Both models feature advanced flame technology, which creates a realistic fire experience, enhancing the ambiance of any space.

The CGCDV42NR and CGCDV42PR models take utility and design a step further. The ‘CG’ signifies these are contemporary gas fireplaces that come with a range of customizable options, including different face designs and finishes that can seamlessly fit into any modern home décor. Both the NR (natural gas) and PR (propane) versions showcase high efficiency, providing powerful heat alongside lower emissions, making them environmentally conscious choices.

All these models are equipped with modern ignition systems that ensure user-friendly operation. For instance, the featured electronic ignition provides reliable and quick startup, while safety components like flame sensors guarantee peace of mind during use. Additionally, these fireplaces offer remote control capabilities for added convenience.

Another notable characteristic is the option for ceramic glass fronts, which are not only aesthetically pleasing but also enhance heat efficiency, allowing space to warm up quickly. With different logs and decorative media options, users can create their ideal fireplace ambiance, customizing the interior look to match personal preferences.

In summary, the Desa VC42P, VC42N, CGCDV42NR, and CGCDV42PR models exemplify a harmonious blend of design, technology, and functionality. These fireplaces are not just heat sources; they are statement pieces that elevate living spaces while providing convenient heating solutions that cater to modern lifestyles. Whether using natural gas or propane, these units stand out with their reliability, efficiency, and aesthetic options, making them a popular choice for homeowners looking to enhance their comfort and home value.