Desa K42EN, K42EP installation manual Wiring Diagram, Optional Remote Control

Page 23

FIREPLACE INSTALLATION

Optional Remote Control Installation

WIRING DIAGRAM

23

FIREPLACE INSTALLATION

Continued

OPTIONAL REMOTE CONTROL

INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation.

1.Open lower louver panel.

2.The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 45).

3.Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 46). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Close lower louver panel.

Fireplace

Receptacle

Remote Control

Receiver

Extension Cord

Ignition

Module Plug

Figure 45 - Installing the WRC Remote Receiver

Battery Cover

12 Volt Battery

Back of

Pull to Remove

Handset

Insulation Tab

 

Figure 46 - Installing Battery into Back of Handset

WIRING DIAGRAM

 

Pilot

 

Burner

INCOMING MAIN

Pilot Gas

GAS SUPPLY

 

Line

 

MV

 

TH

EV1

PV/MV

TR

 

 

GND

 

PV

 

IGN

EV2

24V AC

STEP DOWN

TRANSFORMER

120V AC

GAS LINE TO

BURNER

WALL SWITCH

(NOT SUPPLIED)

ON

OFF

BLACK

INCOMING

 

WHITE

120V AC

GREEN

(FUSE BOX

OR BREAKER)

BLACK

WHITE

GREEN

ELECTRICAL RATING:

120v, 60Hz, 0.7A

OPTIONAL

REMOTE

CONTROL

For morevisit www..com

111922-01C

Image 23
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Number Description High Altitude InstallationCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Model BK InstallationBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Installation Items NeededRemoving Louver Panels Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Removing Glass Door Cleaning Glass DoorWall Switch Installation Installing LOGS, Lava Rock and Glowing EmbersOptional Remote Control Wiring DiagramTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Parts Under Warranty Replacement Parts Service HintsTechnical Service SpecificationsModels Illustrated Parts BreakdownVK42N, VK42NH, VK42P, VK42PH Parts ListBurner Assembly for Models VK42EN, VK42ENH, VK42EP, VK42EPH Burner Assembly for Models VK42N, VK42NH, VK42P, VK42PH Accessories Owners Registration Form Postage Required 111922-01C Warranty Information