Desa FVMR24, FVMR18 installation manual Vented Natural GAS Logs, Safety Information

Page 2

VENTED NATURAL GAS LOGS

SAFETY

INFORMATION

WARNINGS

WARNING: Keep flue open when operating unit.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this log set. Im- proper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.

WARNING: Any change to this log set or its controls can be dangerous.

1.This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is con- vertible for use with propane/LP, using the GA9000 or GA9100 pilot kit.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.Never install the log set

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the log set

in high traffic areas

in windy or drafty areas

4.Before installing in a solid fuel burn- ing fireplace, the chimney flue and fire- box must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage.

5.You must operate this log set with a fire- place screen in place. Make sure fireplace screen is closed before running log set.

6.This log set is designed to be smoke- less. If logs ever appear to smoke, turn off appliance and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and the burning of manu- facturing residues. You may wish to add more ventilation by opening a window.

7.To reduce the creation of soot, follow the instructions in Cleaning and Main- tenance, page 13.

8.Do not allow fans to blow directly into the fireplace. Avoid any drafts that al- ter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting.

9.Do not use a blower insert, heat ex- changer insert or other accessory not approved for use with this log set.

10.This log set needs fresh, outside air ven- tilation to run properly. See Air for Combustion and Ventilation, pages 4 through 6.

11.Do not run log set

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.

13.Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing igni- tion. Log set will remain hot for a time after shutdown. Allow surface to cool before touching.

14.Carefully supervise young children when they are in the room with log set.

15.Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room appliance and to replace any part of the control system (if using GA9000 or GA9100) and any gas con- trol which has been under water.

16.To help prevent breakage, new logs must be broken-in (see Curing Logs page 12).

17.Turn log set off and let cool before ser- vicing, installing, or repairing. Only a qualified service person should install, service, or repair log set.

2

901261

Image 2
Contents For Use with Log Sets OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Vented Natural GAS LogsRemote Control Ready Millivolt Safety VALVE/ Pilot KIT Local Codes Unpacking Optional Product FeaturesON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP Conversion Remote Control AccessoriesUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Appliance Location Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsVenting Specifications for Installation InstallationFlue Opening Specifications Check GAS TypePressure Testing Gas Supply Piping System Installing Damper ClampConnecting to GAS Supply Installation Items NeededKit Assembly Hearth KIT Assembly and InstallationOptional GA9000 ON/OFF Safety VALVE/PILOT KIT Assembly Installation and Gas ConnectionPropane/LP Gas Conversion Gas Control Valve with Ther- mocouple and PilotAdding PAN Material Testing Burner for LeaksInstalling the Grate and Logs Operating Appliance To Turn OFF GAS To Appliance Cleaning and MaintenanceTroubleshooting Shutting Off Burner Only pilot stays litClean pilot see Cleaning and Mainte Gas leak. See Warning statement at Illustrated Parts Breakdown FVMR18 FVMR24Parts List KEY Part Number for FVMR18 FVMR24 Description QTYLOG SET Models FMLR18, and FMLR24 KEY Part Number for FMLR18 FMLR24 Description QTYReplacement Parts AccessoriesWarranty Information International

FVMR24, FVMR18 specifications

Desa FVMR18 and FVMR24 are innovative models that stand out in the world of HVAC (Heating, Ventilation, and Air Conditioning) systems. Designed for modern living and commercial environments, these units combine efficiency, performance, and advanced technology to meet diverse climate control needs.

The FVMR18 is designed for residential spaces, featuring a compact and sleek design that easily fits into various interior layouts. Its primary strength lies in its energy efficiency, boasting an impressive SEER (Seasonal Energy Efficiency Ratio) rating. This not only reduces overall power consumption but also minimizes utility bills, aligning with eco-friendly initiatives. The FVMR24, on the other hand, caters to larger areas, including commercial buildings, offering enhanced cooling and heating capabilities.

Both models utilize inverter technology, which allows them to adjust the compressor speed based on the ambient temperature. This means the units can operate more quietly and sustainably, delivering just the right amount of heating or cooling without the drastic fluctuations typical of conventional systems. The inverter technology also contributes significantly to the longevity of the unit, preventing wear and tear associated with frequent restarts.

A standout feature of both the FVMR18 and FVMR24 units is their advanced air filtration system. Equipped with HEPA filters, these models not only provide optimal temperature control but also ensure a clean and healthy indoor environment by capturing dust, allergens, and other airborne particles. This is particularly beneficial for those with respiratory issues or allergies.

Another key characteristic is the user-friendly interface, which includes a smart remote control and compatibility with smart home systems. This allows users to easily adjust temperatures, set timers, and monitor energy consumption through mobile applications. Additionally, both units are designed with quiet operation technology, ensuring minimal noise disruption, which is crucial in residential and office settings.

In summary, Desa FVMR18 and FVMR24 models represent a blend of cutting-edge technology and user-centric features. With their efficient performance, advanced filtration, and smart capabilities, they effectively address the diverse demands of contemporary climate control, making them a valuable investment for both home and business environments.