Desa VMH10TPA Optional Mantel Installation, Mantel Clearances for Built-In Installation

Page 10

® VMH10TPA

VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE

INSTALLATION

Continued

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

If your installation does not meet the below minimum clearances, you must:

• raise the mantel to an acceptable height,

OR

• remove the mantel.

Mantel Shelf

Note:

10"

8"

All vertical

measurements

6"

are from top of

2 1/2"

fireplace

opening to bottom of mantel shelf. All measurements are in inches.

13"

16"

19"

21"

Side of

Firebox

Figure 11 - Minimum Mantel Clearances for Built-In Installation

OPTIONAL MANTEL

INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installa- tion. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3400T, page 11).

1.Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside.

2.Place fireplace on wood base.

3.Place mantel around fireplace/base as- sembly.

4.Assemble brass trim kit. See Assem- bling Brass Trim, page 11.

5.Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 12).

6.Align brass trim kit for flush fit around opening.

7.Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 12).

Shoulder

Screws

Hole for 3" wood screw

for attaching fireplace to mantel

Assembled

Brass Trim

8.Place assembly next to wall at installa- tion location.

9.Remove brass trim kit and mantel. Be careful not to damage wall or mantel.

10.Attach wood base to floor with two 1 3/4" black screws provided (see Figure 13). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 14).

11.Install gas line. See Connecting To Gas Supply, page 14.

12.Check for leaks. See Checking Gas Connections, page 16.

13.Place mantel around fireplace. Be care- ful not to damage wall or mantel.

14.Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 12).

15.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the man- tel. The openings are located at top be- hind the area for the brass louvers (see Figure 13).

16.Reinstall top brass louvers.

Hole for 3" wood screw for attaching fireplace to wooden base

Figure 12 - Attaching Brass Trim to Fireplace

1 3/4" Screw

Wood Base

Figure 13 - Attaching Wood Base to Floor

10

104407

Image 10
Contents VENT-FREE PROPANE/LP GAS Compact Classic Hearth Fireplace What to do if YOU Smell GASSafety Information VMH10TPALocal Codes Product FeaturesProduct Identification UnpackingAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Low instructions onOptional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Blower Assembly Installing Blower Accessory GA3400TRemoving Upper Louver Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve For Built-In Installation Extension CordConnecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Operating BlowerPilot Flame Pattern Inspecting BurnerBurner Flame Pattern Troubleshooting Observed Problem Possible Cause RemedyPane/LP gas company Gas leak. See Warning statement at Technical Service Cleaning and MaintenanceService Hints Cleaning Burner Injector Holder and Pilot AIR Inlet HoleIllustrated Parts Breakdown VMH10TPAParts List KEY VMH10TPA Description QTYParts Under Warranty SpecificationsReplacement Parts Parts not Under WarrantyAccessories Warranty Information

VMH10TPA specifications

Desa VMH10TPA is a versatile and innovative heating solution designed to meet the demands of modern living environments. This gas-powered heater is part of a broader trend towards efficient, reliable, and user-friendly heating systems that cater to both residential and commercial spaces. With its robust construction and advanced features, the VMH10TPA stands out in the market as a dependable option for those looking to maintain a comfortable atmosphere during the colder months.

One of the main features of the Desa VMH10TPA is its efficiency. The heater boasts a high heating capacity while consuming minimal gas, making it economical for users concerned about energy costs. It is designed to provide consistent warmth while adhering to strict environmental standards, ensuring that installations comply with local regulations concerning emissions and energy use. The unit's design includes a state-of-the-art burner system that maximizes heat distribution, ensuring that rooms are warmed quickly and evenly.

In terms of technology, the VMH10TPA utilizes advanced electronic ignition systems. This feature not only simplifies the ignition process but also enhances safety by reducing the risk of gas leaks associated with manual lighting methods. Additionally, the heater is equipped with temperature control settings, allowing users to customize their heating experience according to their needs.

Another notable characteristic is its compact and aesthetically pleasing design. The VMH10TPA is engineered for easy installation, with options for both wall-mounted and free-standing configurations. Its sleek appearance allows it to blend seamlessly into various interior decors without being an eyesore.

Safety is a paramount consideration in the design of the Desa VMH10TPA. The heater is outfitted with multiple safety features, including automatic shut-off mechanisms that activate in the event of a malfunction or abnormal operation, providing peace of mind to users.

In summary, the Desa VMH10TPA is an efficient, technologically advanced, and user-friendly heating solution. With its combination of high performance, safety features, and stylish design, it caters to a wide range of heating needs, making it an excellent choice for anyone seeking a reliable heater. As energy efficiency and user safety continue to be top priorities, the Desa VMH10TPA represents a significant step towards achieving these goals in home heating technology.