Desa VMH10TPA installation manual Inspecting Burner, Pilot Flame Pattern, Burner Flame Pattern

Page 19

OWNER’S MANUAL

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 31 shows a correct pilot flame pat- tern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

If pilot flame pattern is incorrect, as shown in Figure 32

turn fireplace off (seeTo Turn Off Gas to Appliance, page 18)

seeTroubleshooting, pages 20 through 22

Thermocouple

Pilot Burner

Figure 31 - Correct Pilot Flame Pattern (Actual Pilot May Vary From Illustration)

Pilot Burner

Thermocouple

Figure 32 - Incorrect Pilot Flame Pattern (Actual Pilot May Vary From Illustration)

BURNER FLAME PATTERN

Figure 33 shows a correct burner flame pattern. Figure 34 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows the flame consistently higher than one inch above the log.

If burner flame pattern is incorrect, as shown in Figure 34

turn fireplace off (seeTo Turn Off Gas to Appliance, page 18)

seeTroubleshooting, pages 20 through 22

Top of Flame About

One Inch Below Logs

Figure 33 - Correct Burner Flame Pattern

Top of Flame Consistently About One Inch Higher Than Logs

Figure 34 - Incorrect Burner Flame Pattern

104407

19

Image 19
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS Compact Classic Hearth FireplaceVMH10TPA Safety InformationUnpacking Product FeaturesProduct Identification Local CodesAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeLow instructions on BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Installing Blower Accessory GA3400TRemoving Upper Louver Assembly Installing Blower AssemblyInstall the switch plate on the valve Extension Cord For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions Operating Blower Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationPilot Flame Pattern Inspecting BurnerBurner Flame Pattern Observed Problem Possible Cause Remedy TroubleshootingPane/LP gas company Gas leak. See Warning statement at Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceService Hints Technical ServiceVMH10TPA Illustrated Parts BreakdownKEY VMH10TPA Description QTY Parts ListParts not Under Warranty SpecificationsReplacement Parts Parts Under WarrantyAccessories Warranty Information

VMH10TPA specifications

Desa VMH10TPA is a versatile and innovative heating solution designed to meet the demands of modern living environments. This gas-powered heater is part of a broader trend towards efficient, reliable, and user-friendly heating systems that cater to both residential and commercial spaces. With its robust construction and advanced features, the VMH10TPA stands out in the market as a dependable option for those looking to maintain a comfortable atmosphere during the colder months.

One of the main features of the Desa VMH10TPA is its efficiency. The heater boasts a high heating capacity while consuming minimal gas, making it economical for users concerned about energy costs. It is designed to provide consistent warmth while adhering to strict environmental standards, ensuring that installations comply with local regulations concerning emissions and energy use. The unit's design includes a state-of-the-art burner system that maximizes heat distribution, ensuring that rooms are warmed quickly and evenly.

In terms of technology, the VMH10TPA utilizes advanced electronic ignition systems. This feature not only simplifies the ignition process but also enhances safety by reducing the risk of gas leaks associated with manual lighting methods. Additionally, the heater is equipped with temperature control settings, allowing users to customize their heating experience according to their needs.

Another notable characteristic is its compact and aesthetically pleasing design. The VMH10TPA is engineered for easy installation, with options for both wall-mounted and free-standing configurations. Its sleek appearance allows it to blend seamlessly into various interior decors without being an eyesore.

Safety is a paramount consideration in the design of the Desa VMH10TPA. The heater is outfitted with multiple safety features, including automatic shut-off mechanisms that activate in the event of a malfunction or abnormal operation, providing peace of mind to users.

In summary, the Desa VMH10TPA is an efficient, technologically advanced, and user-friendly heating solution. With its combination of high performance, safety features, and stylish design, it caters to a wide range of heating needs, making it an excellent choice for anyone seeking a reliable heater. As energy efficiency and user safety continue to be top priorities, the Desa VMH10TPA represents a significant step towards achieving these goals in home heating technology.