O. Inspect the Venting System

The fi replace venting system is designed and constructed to develop a positive fl ow adequate to remove fl ue gases to the outside atmosphere. See fi replace installation instructions.

A spillage test must be made before the installed appliance is left with the consumer.

Close all doors and windows in the home.

Light the log set (see Lighting Instructions).

After three minutes, test with a smoke match, smoke candle, stick incense or cigarette 1 in. below the top of the opening (lintel) moving across the full width. If spillage (smoke down into the room) occurs, it will most likely be near the top, outside corners.

Possible cures if spilling occurs:

The damper needs to be opened further.

The fi replace opening needs to be reduced by adding a drop panel across the top under the lintel.

The air supply from outdoors needs to be increased. Open the outside air kit if the appliance is so equipped, or crack open a door or window.

If necessary, seek expert advice. Do not operate this appliance.

Cleaning

Periodic examination and cleaning of the venting system of the fireplace should be done before initial use and at least annually by a qualifi ed agency.

Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev C • 12/05

13

Image 13
Contents Commonwealth of Massachusetts What to do if you smell gasListing Label Information/Location Homeowner Reference InformationTools and Supplies Needed Design and Installation ConsiderationsFire Risk Exhaust Fumes Risk Gas Supply Connection Appliance CertificationGas Pressure Fire Risk Explosion RiskNegative Pressure For Minimum Fireplace DimensionsAsphyxiation Risk For Factory Built FireplacesMeasure Firebox Inspect the Appliance and ComponentsFire Risk Explosion Risk Personal Injury Risk For Natural Gas InstallationDamper Stop Clamp Damper Stop Installation Instructions24 in. Grand Oak Series Logs GO24 24 in. Grand Oak Series GO24 Log Placement Instructions 30 in. Grand Oak Series Logs GO30 Step 30 in. Grand Oak Series GO30 Log Placement InstructionsPossible cures if spilling occurs Inspect the Venting SystemLighting Instructions- Match Light For Your Safety Read Before LightingDo not allow soot to build up on the logs Cleaning and Maintenance InstructionsFequently Asked Questions What sort of maintenance do gas logs require?Grand Oak Gas Logs Replacement PartsDescription of Part Qty Decorative GAS LOG Limited Warranty WarrantyDo not Discard this Manual