Vermont Casting ODSHR42 manual Installing the Chimney System, Proper Firestop Spacer Installation

Page 12

ODSHR Outdoor Woodburning Fireplace

Installing the Chimney System

Start by attaching the first chimney section to the collar on top of the fireplace.

Install the pipe as pictured in Figure 17. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.

When installing elbows, only outer pipe will snap- lock. Middle pipes simply slide into position. Be sure to always attach straps on upper elbow to a structural framing member. (Fig. 18)

Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer.

Installing the Firestop Spacer

in the Ceiling Hole

A firestop spacer is used to keep pipe spaced properly and required for safety.

Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.

Hole sizes listed in Figure 12 for angled firestop spac- ers provide minimum required air space to chimney pipe for ceiling thickness up to 8" (203 mm). When combined thickness of ceiling material, ceiling joists and flooring material exceeds 8" (203 mm), adjust- ments must be made in framing to assure that minimum air spaces to chimney are maintained.

Proper Firestop Spacer Installation

Figure 19 shows different installation procedures for both an area that is an attic and an area that is not an attic.

Inner Pipe

Section

Pipe

Rim Hem

Lance

Pipe

Rim

FP558SHR

Fig. 17 Install pipe, listening for the snap-lock to fasten.

Support Structure

Elbow Strap (must be tight)

Ceiling

Elbow StrapHole

Framing

Angle Firestop

Chimney Support

Angled StrapStrap

(must be tight)

FP270/271

Fig. 18 Attach straps to a structural framing member.

If the area above the ceiling is not an attic, po- sition the firestop spacer with the flange on the ceil- ing side and the angled portion extending up into the hole.

If the area above the ceiling is an attic, position the firestop spacer with the flange on the top of the framed hole and the angled portion extending down into the hole.

12

 

Attic Installation

Ceiling Installation

 

Nails (4)

 

 

 

Firestop Spacer

 

Joist

 

 

 

 

Joist

 

Firestop

 

 

Spacer

 

 

 

 

Flange Down Into Hole

 

Nails (4)

 

 

Flange Up Into Hole

FP285

Fig. 19

Installing firestop spacer.

 

 

 

 

 

20002264

Image 12
Contents Odshr Series Table of Contents Safety Information ODSHR42 Series Woodburning Fireplace Front Width Back Width DepthInstallation Exterior Chase InstallationInterior Chase 30˚ Elbow Offsets Illustration KeyPlanning Information Mounting the FireplacePlanning the Chimney Run Ten Foot RuleInstallation Chase InstallationChimney Supports Insulating Fireplace Enclosure for Cold ClimatesStraight-Up Chimney Installation Offset InstallationFraming Chimney Set-UpCutting the Hole Framing the Ceiling HoleChimney Hole Size Angle of Chimney at CeilingPositioning, Safety Strips Securing the Fireplace Installing Outside Air KitInstalling the Chimney System Installing the Firestop Spacer Ceiling HoleProper Firestop Spacer Installation Attic Installation Ceiling InstallationContinue Installing Pipe to Complete Run Install Remainder of Chimney SectionsInstalling Top Housing or Termination Installing Chimney In a ChaseFinish Wall Air Space ClearancesFront View Side View Mantel Clearance No Noncombustible Facing Material Mantel clearancesHearth Installation Side Wall ProtectionExamples of wall shield insulation Example of Determining Hearth Extension Equivalents Example for Common BrickInstalling Line for Gas Logs Gas line accessOdshr Outdoor Woodburning Fireplace Description Part NumberAccessories Accessory Description Model NoRLTCF11L Firebox RecordOdshr Outdoor Woodburning Fireplace For Majestic Fireplaces PRE-ENGINEERED Fireplace Systems Firegrate, Glass Doors, Outside Air SystemFan Motor Liners Refractory or MetalCFM Corporation