Vermont Casting EWF36 Optional Accessories, Fan Kit, Trim Kits, Screen Kit

Page 29

Vermont Castings EWF36A

Optional Accessories

Fan Kit

FK26 Fan

The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat provides for variable fan speeds.

Specifications

115 Volt / 60Hz / .75 Amps

Maintenance

The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surround- ing area is required.

Installation

1.Place fan assembly at the back of the unit between hearth supports. Attach using velcro strips provided. (Fig. 33)

2.Install thermal sensor (snapstat) on bottom of firebox by sliding between bracket and firebox.

3.Place electronic fan speed control box (rheostat) to side bracket. Fasten fan speed control box with #10 - 24 hex nuts.

4.If the EB-1 receptacle box (Pt. #ZA1200) was cor- rectly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket.

The fireplace, when installed must be electrically connected and grounded in ac-

cordance with local codes, with the current CSA C22.1 Canadian Electrical Code or for US installations, follow local codes and the National Electrical Code, ANSI/NFPA No.

70.

Any electrical rewiring of this fan must be completed by a qualified electrician.

Turn off all power before hook up.

 

 

Heat Sensor

Electrical

 

Fan

(Snapstat)

 

Box

 

 

 

 

 

Fan Speed Switch

 

 

(Rheostat)

FP1323

 

 

 

Fig. 33

FK26 fan placement.

 

Trim Kits

A cast face trim kit and a cast louvre kit are available to enhance the look of your EWF36A fireplace. Installation instructions are included with the kit.

Model Description

EWF36ACFTK

Cast Face Trim Kit

EWF36ACLK

Cast Louvre Kit

Screen Kit

An optional spark screen, EWF36S, is available to allow the fireplace to be operated with the doors fully open.

NOTE: When operated with the doors open and the screen in place, the damper MUST be in the open position.

20005167

29

Image 29
Contents EWF36A Introduction Table of ContentsPrecautions Safety InformationDescription DraftsEWF36A Woodburning Fireplace SpecificationsFireplace and chase parts identification Chase InstallationChimney Requirements Offset Installations Mounting the Fireplace Planning InformationPlanning the Chimney Run Ten Foot RuleInsulating Fireplace Enclosure for Cold Climates InstallationChimney Supports Offset Installation Straight-Up Chimney InstallationFraming EB1 Receptacle HookupCeiling Chimney Hole Possible Obstructions Positioning, Safety Strips Securing the FireplaceCutting the Hole Framing the Ceiling HoleInstallation Precautions Installation InstructionsInstallating Outside Air Kit AK-MST Outside Air Kit is now installed and ready for use Installing the Chimney SystemProper Firestop Spacer Installation Installing the Firestop Spacer Ceiling HoleContinue Installing Pipe to Complete Run Canadian Requirements For Insulation ShieldInstall Top Housing or Termination Install Remainder of Chimney SectionsInstalling Chimney in a Chase Penetrating the RoofSide Wall Protection Finish WallMantels Examples of wall shield insulation Hearth InstallationMinimum Wall Clearances Attach Handles OperationEWF36A Controls Primary Air ControlFan Use the Air Control Settings That Work Best for YouGlass Doors Burn Only High-Quality WoodSpecial Tactics for Cold-Climate Heating Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Remove and Store Ash Safely Maintenance Removing, Cleaning or Replacing the Combustor When to Suspect a Combustor ProblemHow to Replace Gaskets Inspecting the CombustorChimney System Clean Chimney System is Safer and Works BetterReplacing the Door Gaskets Replace Damaged Door Glass ImmediatelyFireplace Daily Maintenance ScheduleYearly Spring Cleaning TCS8A Chimney ComponentsEWF36A Fireplace EWF36A Fireplace Fan Kit Optional AccessoriesTrim Kits Screen KitVermont Castings EWF36A Warranty CFM Corporation