Vermont Casting EWF36 installation instructions Remove and Store Ash Safely

Page 21

Different results may be experienced even in the same installation if you switch from burning good, dry wood to wood that is partially rotted or inadequately seasoned.

To compensate for these factors in cold climates, it may be necessary to operate the EWF36A with the air con- trol set to a higher level more of the time.

Remove and Store Ash Safely

Check the ash pan before reloading the stove, and empty if necessary using the following procedure:

Open the damper.

Open the load door.

Remove the ash pans from under the hearth brick. The EWF comes with a cover for the ash pan. To install this cover, hold just above the ash pans with the handle on the cover closest to you. Slide the cover onto the top of the pan as you pull the pan out. As the pan slides out, the flange on the back of the cover should slide into the slot in the back of the ash pan and the flange on the front of the cover will slide over the handle on the ash pan. CAUTION: Do not pull the pan out too far before the cover engages the slot. Ash may contain hot coals and must be treated with extreme care. Hold the covered ash pan with both hands to avoid dropping or spilling the ashes.

Take the pans outdoors and empty the ash into an ash container.

Before replacing the ash pan, clear away any ash that has spilled over the sides and back of the pan.

Replace the ash pans and front door.

Vermont Castings EWF36A

Empty the ash pans regularly, typically every one to three days. The frequency will vary depending on how you operate your EWF36A: If you burn more wood at higher heat output settings, and ash will accumulate faster.

Ash should be removed frequently and placed outdoors in a metal container with a tight-fitting lid. The closed container of ash should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ash is disposed of by burial in soil or otherwise locally dispersed, it should be retained in the closed container until all cin- ders have thoroughly cooled. Wood ash may be used as a garden fertilizer.

CAUTION: Never use your household or shop vacuum cleaner to remove ash from the fireplace; always re- move and dispose of the ash properly.

20005167

21

Image 21
Contents EWF36A Introduction Table of ContentsPrecautions Safety InformationDescription DraftsEWF36A Woodburning Fireplace SpecificationsFireplace and chase parts identification Chase InstallationChimney Requirements Offset Installations Mounting the Fireplace Planning InformationPlanning the Chimney Run Ten Foot RuleInstallation Chimney SupportsInsulating Fireplace Enclosure for Cold Climates Offset Installation Straight-Up Chimney InstallationFraming EB1 Receptacle HookupCeiling Chimney Hole Possible Obstructions Positioning, Safety Strips Securing the FireplaceCutting the Hole Framing the Ceiling HoleInstallation Instructions Installating Outside Air KitInstallation Precautions AK-MST Outside Air Kit is now installed and ready for use Installing the Chimney SystemProper Firestop Spacer Installation Installing the Firestop Spacer Ceiling HoleContinue Installing Pipe to Complete Run Canadian Requirements For Insulation ShieldInstall Top Housing or Termination Install Remainder of Chimney SectionsInstalling Chimney in a Chase Penetrating the RoofFinish Wall MantelsSide Wall Protection Examples of wall shield insulation Hearth InstallationMinimum Wall Clearances Attach Handles OperationEWF36A Controls Primary Air ControlFan Use the Air Control Settings That Work Best for YouGlass Doors Burn Only High-Quality WoodStarting and Maintaining a Wood Fire Reloading and Reviving a Wood FireSpecial Tactics for Cold-Climate Heating Remove and Store Ash Safely Maintenance Removing, Cleaning or Replacing the Combustor When to Suspect a Combustor ProblemHow to Replace Gaskets Inspecting the CombustorChimney System Clean Chimney System is Safer and Works BetterReplacing the Door Gaskets Replace Damaged Door Glass ImmediatelyMaintenance Schedule Yearly Spring CleaningFireplace Daily TCS8A Chimney ComponentsEWF36A Fireplace EWF36A Fireplace Fan Kit Optional AccessoriesTrim Kits Screen KitVermont Castings EWF36A Warranty CFM Corporation