Section C Con’t.
C5
WARNING
Bezels must be replaced one at a time. Removing more than one bezel at a time may cause misalignment of manifold.
Pull the Tube Burner Control Knob off of Valve Stem.
Remove two Screws and two Washers that secure Bezel to the Control Panel. Save removed Bezel for converting back to LP Tank Gas.
Install new Natural Gas Bezel provided with Kit (see illustration below) in place of old Bezel onto Control Panel, and secure using previously removed Screws and Washers. Assure proper alignment with control knob before fully tightening. Note: New bezels will change the rotation for the control knob to properly control ignition and flames for your grill.
Press Control Knob back onto Valve Stem. Make adjustments needed to Bezel for free movement of Control Knob
Repeat for each Bezel.
OFF
Bezels
Lock Washers
Hi
Valve
Stem
Low
Screws
Med
Large Bezel
C6
Tube Burner Control Knobs
Reinstall Tube Burners
Insert Tube Burners into Firebox Burner holes over Valves with Ignitor Assembly downward, making sure Tube Burner engages Valve properly. See illustration below.
Secure Tube Burners to Burner Brackets with previously removed Hitch Pins. Replace Carryover tubes and secure with Hitch Pins previously removed. Reference illustration C1.
Reinstall Searing Burner with previously removed Screws, Lock Washers and Flat Washers. Reference illustration C3. Make sure Searing Burner engages Valve properly. See illustration below.
Correct | Incorrect | Correct | Incorrect |
engagement | engagement | engagement | engagement |
Tube Burner | Searing Burner |
12