Section F Con’t.
F2
Using the provided Orifice Driving Tool, unscrew the Orifice from the end of the Sideburner Valve. Save removed Orifice and Orifice Driving Tool for converting back to LP.
DO NOT replace the Orifice. This Valve is designed to work with Natural Gas once Orifice is removed.
Orifice
Orifice Driving Tool
Valve
Orifice Driving Tool
F3
Pull the Sideburner Control Knob off of Valve Stem. Remove the existing Bezel by removing the two Screws and two Washers securing bezel to Shelf fascia. Save removed Bezel for converting back to LP Tank Gas.
Install new Natural Gas Bezel (see illustration below) and press Control Knob back onto Valve Stem.
OFF
Hi
Low
Bezel
Screw
Med
Valve stem
Large Bezel
Washer
Sideburner control knob
19