Troubleshooting (continued)
Problem | Possible Cause |
| Prevention/Solution | |
|
|
|
| |
Burner(s) will not light | ELECTRONIC IGNITION: |
| • See Section I of Electronic Ignition System. | |
using ignitor. | • No spark, no ignition noise. |
| ||
(See Electronic Ignition | • No spark, some ignition noise. |
| • See Section II of Electronic Ignition System. | |
Troubleshooting also) |
| |||
| • Sparks, but not at electrode or at full |
| • See Section III of Electronic Ignition System. | |
|
| strength. |
|
|
Burner(s) will not | • See “GAS ISSUES:” on previous page. |
|
| |
match light. | • Match will not reach. |
| • Use | |
|
| |||
| • Improper method of |
| • See | |
Sudden drop in gas | • Out of gas. |
| • Check for gas in LP cylinder. | |
flow or low flame. | • Excess flow valve tripped. |
| • Turn off knobs, wait 30 seconds and light grill. If flames are still low, | |
|
| |||
|
|
|
| turn off knobs and LP cylinder valve. Disconnect regulator. |
|
|
|
| Reconnect regulator and |
|
|
|
| 30 seconds and then light grill. |
| • Vapor lock at coupling nut/LP cylinder |
| • Turn off knobs and LP cylinder valve. Disconnect coupling nut from | |
|
| connection. |
| cylinder. Reconnect and retry. |
Flames blow out. | • High or gusting winds. |
| • Turn front of grill to face wind or increase flame height. | |
| • Low on LP gas. |
| • Refill LP cylinder. | |
| • Excess flow valve tripped. |
| • Refer to “Sudden drop in gas flow” above. | |
• Grease buildup. |
| • Clean burners and inside of grill/firebox. | ||
| • Excessive fat in meat. |
| • Trim fat from meat before grilling. | |
| • Excessive cooking temperature. |
| • Adjust (lower) temperature accordingly. | |
|
|
|
| |
Persistent grease fire. | • Grease trapped by food buildup around |
| • Turn knobs to OFF. Turn gas off at LP cylinder. Leave lid in position | |
|
| burner system. |
| and let fire burn out. After grill cools, remove and clean all parts. |
|
|
|
| |
Flashback... | • Burner and/or burner tubes are blocked. |
| • Turn knobs to OFF. Clean burner and/or burner tubes. See burner | |
(fire in burner tube(s)). |
|
|
| cleaning section of Use and Care. |
Unable to fill LP | • Some dealers have older fill nozzles |
| • The worn nozzles don’t have enough “bite” to engage the valve. Try | |
cylinder. |
| with worn threads. |
| a second LP dealer. |
One burner does not | • Grease buildup or food particles in |
| • Clean | |
light from other |
| end(s) of carryover tube(s). |
|
|
burner(s). |
|
|
|
|
| Possible Cause |
| Prevention/Solution | |
(If Equipped) |
| |||
|
|
|
| |
Timer does not work | | Dead Battery | | Replace batteries |
(Green light does not | | Batteries installed incorrectly. | | Install batteries correctly. |
flash) | Knob Position did not start the Clean | Push Knob in to start the clean cycle. (Green LED should begin to | ||
|
| Cycle |
| flash) |
|
|
|
|
|
No LED’s will illuminate | | Dead Battery | | Replace batteries |
|
|
|
| |
Red LED next to battery | | Low Battery Strength | Prepare to replace batteries (NOTE: Clean cycle will operate with | |
symbol is illuminated |
|
|
| a weak battery. |
|
|
|
|
|
24