Char-Broil 463251012 Leak Testing Valves, Hose and Regulator, Turn all grill control knobs to OFF

Page 6

Hold coupling nut and regulator as shown for proper connection to LP cylinder valve.

6.Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal on the back-check feature in the LP cylinder valve, resulting in some resistance. An additional one-half to three-quarters turn is required to complete the connection. Tighten by hand only – do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the

connection, do not use this regulator!

DANGER

Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.

WARNING

Outdoor gas appliance is not intended to be installed in or on a boat.

Outdoor gas appliance is not intended to be installed in or on an RV.

Never attempt to attach this grill to the self-contained LP gas system of a camper trailer or motor home.

Do not use grill until leak-tested.

If a leak is detected at any time, STOP and call the fire department.

If you cannot stop a gas leak, immediately close

LP cylinder valve and call LP gas supplier or your fire department!

6

Leak Testing Valves, Hose and Regulator

1.Turn all grill control knobs to OFF.

2.Be sure regulator is tightly connected to LP cylinder.

3.Completely open LP cylinder valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.

4.Brush soapy solution onto areas circled below, or other similar fittings on your grill.

 

 

 

 

 

 

 

 

NOTE: Your grill

 

 

NOTE: Sideburner

 

may NOT be

 

 

shelf fascia not

 

equipped with a

 

 

shown for clarity.

 

sideburner.

 

 

 

 

 

 

5.If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and retighten connections. If leaks

cannot be stopped do not try to repair. Call for replacement

parts.

6.Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.

Image 6
Contents Product Guide Date PurchasedINSTALLER/ASSEMBLER Installation Safety Precautions California PropositionUL listed Overfill Protection LP Liquefied Petroleum GasLP Cylinder Filling Only LP cylinders equipped with this type of valveFor your safety UseDo not household cleaning agents. Damage to gasLP Cylinder Leak Test Leak Testing Valves, Hose and Regulator Connection, do not use this regulatorTurn all grill control knobs to OFF For Safe Use of Your Grill and to Avoid Serious Injury Main Burner Ignitor LightingSideburner Match Lighting General Grill CleaningSideburner Ignitor Lighting Burner Flame CheckCleaning the Burner Assembly Storing Your GrillLimited Warranty Parts List Parts Diagram Assembly Page Bottom shelf Cabinet shelf Front brace Fiber washer 20x1½ screw Upper back Shown a #8x3/8 self-tapping screw Large flat washer 20x1½ screw Side Nut Longer slot at the top Place side burner cooking grate onto side burner shelf Page Regulator Main Burner Conversion Screws Sideburner Conversion Bezel Outdoor Stove & Griddle Conversion Natural Gas Bezel 80007886 Natural Gas Hose Conversion Connecting Your Grill to the Natural Gas Source To the grill. Direction of gas flow is indicated onSocket Troubleshooting Emergencies Possible Cause Prevention/SolutionAUTO-CLEAN Troubleshooting Electronic Ignition SectionPage Mail to / Envíelo a