Coleman 9992-647 manual For Your Additional Safety, Problem Grill too hot

Page 26

Troubleshooting (continued)

Problem: Flame blows out on low setting or has uneven heat distribution.

Possible Causes and Solutions:

1.Check for spider webs or insect nests in the venturi and clean the venturi.

2.Cold grill needs to be preheated for 5 minutes on high setting.

3.The venturi may be misaligned and needs to be lined up over the orifices.

4.Cold and windy weather will require you to move the grill away from the wind.

5.Lack of fuel. Check to see that the cylinder valve is open and that the cylinder has fuel.

Problem: Grill too hot.

Possible Causes and Solutions:

1.Excessive flareups which require the maintenance described in the section titled “IN CASE OF GREASE FIRE”.

2.A damaged orifice or regulator which requires replacement with factory authorized parts.

3.Buildup of grease inside the grill will require cleaning and emptying the grease tray.

4.Choose a lower cooking temperature if using excessively high settings.

Problem: Fire at any connection.

Possible Causes and Solutions:

IMMEDIATELY shut off cylinder valve and allow grill to cool.

1.Gas is leaking from a faulty connection. Tighten connections with an adjustable wrench and replace damaged parts. Perform a leak test on all connections before cooking on the grill again.

Problem: Flame behind control panel or control knob area.

Possible Causes and Solutions:

IMMEDIATELY shut off cylinder valve and allow grill to cool.

1.Check for spider webs or insect nest in the venturi and clean the venturi.

2.Gas is leaking from a faulty connection. Tighten connections with an adjustable wrench and replace damaged parts. Perform a leak test on all connections before cooking on the grill again.

3.The venturi may be misaligned and needs to be lined up over the orifices.

DANGER

If a fire occurs at the cylinder valve, DO NOT attempt to move the cylinder. IMMEDIATELY call the fire department and clear the area. You can safely spray water with a garden hose from a distance of at least 15 feet away from cylinder until firemen arrive.

For Your Additional Safety

Current L.P. gas cylinders are fitted with an Overfill Protection Device (O.P.D.). To insure that you retain this safety-device, take your cylinder to an L.P. gas service station for filling, or when exchanging your cylinder at a cylinder exchange station, request that your replacement cylinder be fitted with the O.P.D. feature.

26

For Your Additional Safety (continued)

YOUR NEW GAS GRILL IS EQUIPPED WITH A TYPE 1 CONNECTION DEVICE WHICH HAS 3 SAFETY FEATURES (FIG. 55):

1.Proof of gas seal between the connector and the cylinder before gas flow takes place.

2.A flow-limiting device designed to limit the flow of gas in the event of a regulator or hose failure.

3.The connection has a thermal shut-off which will stop the flow of gas if the connection reaches a certain temperature.

CURRENT GAS CYLINDERS ARE ALSO EQUIPPED WITH AN OVERFILL PROTECTION DEVICE (O.P.D.) WHICH GREATLY REDUCES THE CHANCE OF ACCIDENTALLY OVERFILLING THE CYLINDER.

SPECIAL NOTE CONCERNING L.P. GAS CYLINDERS:

It is important to insure that your gas cylinder is properly purged before it is filled. If you purchase a new cylinder, please inform your propane gas dealer that this is a new cylinder and needs to be properly purged before being filled.

SPECIAL NOTE CONCERNING TYPE 1 CONNECTION DEVICES:

If you notice very small flames on the burner(s), you may have accidentally activated the flow-limiting device in the Type 1 connection device. Besides a rupture in the gas hose, the flow-limiting device may activate for one of the two following reasons:

1.Opening the burner valves before opening the cylinder valve. SOLUTION: Shut off the burner valves and the L.P. cylinder valve and open in the proper order:

a). Open the L.P. cylinder valve first, then b). Open burner valve and ignite the burner

according to the instructions in this manual for your grill.

IF YOU STILL HAVE A PROBLEM, THEN THERE MAY BE AIR IN THE CYLINDER DUE TO IMPROPER PURGING.

2.The L.P. cylinder was not properly purged before it was filled. SOLUTION: See your L.P. gas supplier.

Fig. 55

Valve

Nipple with

Excess Flow

Thermal

Sensitive

Handwheel

1-5/16" Acme Connection

Regulator

TYPE 1 CONNECTION ILLUSTRATION

Image 26
Contents Use, Care & Assembly Manual Contents General Installation Electrical Attachments Cylinder Specifications Transporting the CylinderFilling and Purging Type Gas Cylinders Take these instructions to the L.P. gas dealerGrill Features 8400 Series Replacement Parts List 8400 Series Replacement Parts List 8400 Series Right Side Shelf Attachment Grill Assembly 8400 SeriesCart Brace Installation Grill Assembly 8400 Series Left Side Shelf AttachmentSide Burner Installation Igniter Battery InstallationInterior Parts Installation LP Cylinder Installation Connecting Type 1 L.P. Gas Cylinders Natural Gas Installation 8400 Series Fixing a Fuel Leak Leak TestingHow to Check for Leaks Start-Up Check List Lighting InstructionsMatch Lighting Main Burners Lighting Main BurnersLighting Side Burner Match Lighting Side BurnerUsing the Rotisserie 8400 Series Electrical Grounding InstructionsMatch Lighting Rotisserie Burner Lighting the Rotisserie BurnerShutting Off the Grill General Use and Correct Burner Flames Grilling Tips and Hints Cooking Methods Care, Maintenance and Cleaning Case of Grease Fire Steps For Cleaning Venturi Cleaning the VenturiTroubleshooting Moving and StorageProblem Fire at any connection For Your Additional SafetyProblem Grill too hot Problem Flame behind control panel or control knob areaColeman¨ Grill Warranty Registration Card Congratulations on Your NEW Coleman Grill Purchase Page Page Page Warranty Coleman Gas Barbecue Grill 5/1 Year Limited Warranty