Weber Summit Gas Griill, 38050 Crossover Ignition System Operations, Replace Igniter Batteries

Page 32

32 MAINTENANCE

CROSSOVER® IGNITION SYSTEM OPERATIONS

If the Crossover® ignition system fails to ignite the LEFT burner in a burner set, light the LEFT burner with a match. If the LEFT burner lights with a match, then check the Crossover® ignition system.

Check that both ignition wires(1,2) are attached properly.

Check that the Crossover® ignition button is activating.

You should hear the igniter sparking.

If the Crossover® ignition system still fails to light, contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

(1 )

(2 )

REPLACE IGNITER BATTERIES

Parts required: 1 AA alkaline battery per igniter.

Unscrew igniter button from bottom of control panel. Remove igniter button and contact spring. Remove old battery and replace with a new AA alkaline battery. Positive end(1) of battery faces up as shown in illustration. Replace spring contact(2) and screw igniter button(3) back down.

ATTENTION: This product has been safety tested and is only certified for use in a specific country. Refer to country designation located on outer carton.

These parts may be gas carrying or gas burning components. Please contact Weber-Stephen Products Co., Customer Service Department for genuine Weber-Stephen Products Co. replacement part(s) information.

WARNING: Do not attempt to make any repair to gas carrying or gas burning components without contacting Weber-Stephen Products Co., Customer Service Department. Your actions, if you fail to follow this product Warning, may cause a fire or an explosion resulting in serious personal injury or death and damage to property.

Image 32
Contents Summit GAS Grill NG US EnglishLiquid Propane GAS Units only For replacement parts call WarrantyCustomer Service Center Roselle Road, Suite Schaumburg, IL For Installation in Canada Gas Supply TestingGeneral Instructions OperatingGrilling Methods Cleaning Install GAS Supply Leak Check PreparationGeneral Specifications for Piping Gas Line PipingCheck for Gas Leaks GAS InstructionsConnect GAS Supply Check for GAS Leaks Remove Control Panel Check for GAS LeaksSummit a Reinstall Control Panel Grilling MethodsPreheating Covered cookingIndirect Cooking Operating InstructionsDirect Cooking Crossover Ignition System Grilling Tips & Helpful HintsLighting To Extinguish Manual LightingSide Burner Lighting Instructions Lighting with IgniterLighting only the side burner Lighting the side burner if the main burners are litSummit B, Cc, D Manually Lighting Side Burner Manual LightingTo use the smoker Using the SmokerCleaning the smoker Lighting the Smoker Burner Manually Lighting the Smoker Burner Rotisserie Assembly Install the motor bracketAttach the motor Put the spit forks on the rotisserie shaftUsing the Rotisserie Important Safeguards CookingLighting the Rotisserie Burner To Extinguish Manually Lighting the Rotisserie Burner Operating Instructions Problem Check Cure Side Burner Troubleshooting Side Burner MaintenanceRotisserie Troubleshooting Burner does not lightWeber Spider /INSECT Screens MaintenanceInspection and cleaning of the Spider/Insect screens Main Burner Cleaning Procedure Main Burner Flame PatternReplace Main Burners Turn off the gas supplyMaintenance BB Crossover Ignition System Operations Replace Igniter Batteries