Weber 55827 manual Check for GAS Leaks

Page 10

10

GAS INSTRUCTIONS

 

 

 

CHECK FOR GAS LEAKS

 

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory-made connections have been thoroughly checked for gas leaks. The burners have been flame-tested. As a safety precaution however, you should recheck all fittings for leaks before using your Weber® gas barbecue. Shipping and handling may loosen or damage a gas fitting.

WARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: a soap and water solution, and a rag or brush to apply it. Make sure side burner is OFF. Remove valve control knob and screws. Remove porcelain top.

To perform leak checks: Slide back the collar of the quick disconnect. Push male fi tting of the hose into the quick disconnect, and maintain pressure(1). Slide the collar closed(2). If it does not engage or lock, repeat procedure.

Gas will not fl ow unless the quick disconnect is properly engaged. Turn on gas supply.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

WARNING: Do not ignite burners when leak checking.

(1)

(2)

Image 10
Contents Genesis GAS Grill NG US EnglishContents Liquid Propane GAS Units only Customer Service Center Roselle Road, Suite Schaumburg, IL WarrantyFor replacement parts call General Instructions For Installation in CanadaGas Supply Testing StorageCleaning CookingGeneral Specifications for Piping Install GAS SupplyGAS Instructions Gas Line PipingCheck That ALL Burner Valves are OFF Remove Control Panel and Burner Control KnobsSilver a & B Gold B Platinum B Check the Flexible Hose to Manifold ConnectionCheck for GAS Leaks Silver C Gold C Platinum CLighting Operating InstructionsSilver C Silver a & B Gold B & C Platinum B & C Main Burner LightingSilver C Gold B & C Platinum B & C Silver a & BManual Lighting Lighting only the side burner Lighting the Side BurnerLighting with Igniter Lighting the side burner if the main burners are litTroubleshooting Problem Check CureSide Burner Troubleshooting Side Burner MaintenanceInspection and cleaning of the Spider/Insect screens MaintenanceAnnual Maintenance Weber Spider /INSECT ScreensReplacing Main Burners Main Burner Cleaning ProcedureMain Burner Flame Pattern Turn off the gas supplyGenesis a & B Genesis CWEBER-STEPHEN Products CO