16 SIDE BURNER TROUBLESHOOTING
PROBLEM | CHECK | CURE |
|
|
|
Side Burner does not light. | Is gas supply off? | Turn supply on. |
|
|
|
Flame is low in HIGH position | Is the fuel hose bent or kinked? | Straighten hose. |
|
|
|
Push button ignition does not | Does burner light with a match? | If match lights burner, check igniter (see below). |
work. |
|
|
|
|
|
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
SIDE BURNER MAINTENANCE
WARNING: All gas controls and supply valves should be in the OFF position.
Make sure black wire is connected between the igniter and electrode
(1). Make sure white wire is connected between the igniter and grounding clip
(2). Spark should be a white/blue color, not yellow.
1)Igniter Wire
2)Ground wire
3)Burner
Side Burner Grate
Side Burner Cap
Side Burner Ring & Head
Igniter Electrode
Control Knob
(3) |
(1) |
(2) |
(2) |
(1) |