Gas Instructions
Install Gas Supply
General Specifications for Piping
Note - Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must confirm to the latest edition of ANSI Z223.1. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL. Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifications.
■This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).
■A manual
■An additional manual
■The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a
■The quick disconnect fitting can be installed horizon- tally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.
■The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.
■Pipe compound should be used which is resistant to the action of natural gas when connections are made.
■The outdoor connector must be firmly attached to rigid,
permanent construction.
WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.
Gas supply
Inside wall
Outside wall
Shut off
This is a typical installation of a Weber® natural gas barbecue. Local codes may require different installations.
Locking shut off
Quick | 3/ | " Pipe | 1/ " Pipe | |
disconnect | 8 | 2 | ||
|
| nipple | nipple | |
|
|
|
|
|
|
|
|
|
|
C305_NG.b | Do Not Use |
|
Gas Line Piping
■If the length of the line required does not exceed 50 feet, use a 5/8" O.D. tube. One size larger should be used for lengths greater than 50 feet.
■Gas piping may be copper tubing, type K or L; polyeth- ylene plastic tube, with a minimum wall thickness of
.062 inch; or standard weight (schedule 40) steel or wrought iron pipe.
■Copper tubing must be
■Plastic tubing is suitable only for outdoor, underground use.
■Gas piping in contact with earth, or any other material which may corrode the piping, must be protected against corrosion in an approved manner.
■Underground piping must have a minimum of 18" cover
Test Connections
All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed proce- dures in the latest edition of ANSI Z223.1
DANGER
Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property.