Weber 55024 manual Install Gas Supply General Specifications for Piping

Page 14

Connect side burner to manifold WARNING: Make sure gas supply is off.

Connect the side burner hose as follows:

1)Slide back the collar of the quick disconnect on the manifold.

2)Push the male fitting of the side burner hose into the quick disconnect, and maintain pressure. Slide the collar closed.

Quick disconnect will be engaged.

Check to be sure the side burner valve is OFF. Push the side burner control knob down and turn it clockwise. If it doesn’t turn, the valve is OFF. If it does turn, continue turning it clockwise until it stops, then the burner valve is OFF.

(1)

(2)

Install Gas Supply

General Specifications for Piping

Note - Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must confirm to the latest edition of ANSI Z223.1. WE RECOMMEND THAT THIS INSTALLATION BE DONE BY A PROFESSIONAL.

Some of the following are general requirements taken from ANISI Z223.1 latest edition for complete specifications.

This barbecue is designed to operate at 7 inches of water column pressure (.2526 psi).

A manual shut-off valve must be installed outdoors, immediately ahead of the quick disconnect.

An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line

The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The quick disconnect fitting is a hand-operated device that automatically shuts OFF the flow of gas from the source when the barbecue is disconnected

The quick disconnect fitting can be installed horizontally, or pointing downward. Installing the fitting with the open end pointing upward can result in collecting water and debris.

The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected.

Pipe compound should be used which is resistant to the action of natural gas when connections are made.

The outdoor connector must be firmly attached to rigid, permanent construction.

WARNING: Do not route the 12 foot hose under a deck. The hose must be visible.

 

Gas supply

Inside wall

 

Outside wall

 

 

Shut off

Quick Disconnect

Locking shut off

 

C-2

Image 14
Contents Genesis GOLD-C Liquid Propane GAS Units only Warranty Customer Service Center South Hicks Road Palatine, ILContents Storage For Installation in CanadaOperating Gas Supply Testing Genesis Gold-C NG Manifold, Hose and regulator assembled Page Remove Packaging from Grill Remove Grill from Lower PackagingPage Assembly Instructions Install the slide out bottom trayInstall the bottom shelf Installing the Warm-Up BasketInstalling the warming rack Install the condiment basketCheck that all burner valves are off Install Left Work SurfaceInstall Side Burner Assembly Install Gas Supply General Specifications for Piping Remove the control panel Gas Line PipingTest Connections Check for gas leaksReinstall control panel after checking for gas leaks Lighting To ExtinguishManual Lighting Lighting the Side Burner Lighting only the side burnerStorage CleaningCooking Annual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsWeber Spider Stopper Guards General MaintenanceMain Burner Cleaning Procedure Replacing Main Burners Crossover Ignition System Operations Orange flame, in conjunction with Flame is low when burner is onBurners burn with a yellow or Smell of gasFlame is very yellow Side Burner does not lightFlame is low in High position Conjunction with the smell of gas